Time-resolved cryo-EM using Spotiton
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present an approach for preparing cryo-electron microscopy (cryo-EM) grids to study short-lived molecular states. Using piezoelectric dispensing, two independent streams of ~50-pl droplets of sample are deposited within 10 ms of each other onto the surface of a nanowire EM grid, and the mixing reaction stops when the grid is vitrified in liquid ethane ~100 ms later. We demonstrate this approach for four biological systems where short-lived states are of high interest. A spraying-mixing approach for preparing cryo-EM grids using the Spotiton robot allows time-resolved observations of short-lived biomolecular states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446 · cited 7×
“Briefly, 2,158,345 particles were auto picked and used for 2 rounds of 2D classification in Relion3.”
Influential
Cited by
(2022) · doi:10.3389/fmolb.2022.1044509 · Cited by 20
Bongiovanni, G., Harder, O. F., Drabbels, M., & Lorenz, U. J. (2022) · doi:10.1101/2022.09.14.507962 · Cited by 20
Wranik, M., Kepa, M. W., Beale, E. V., James, D., Bertrand, Q., Weinert, T., Furrer, A., Glover, H., Gashi, D., Carrillo, M., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-43523-5 · Cited by 14
Factors affecting macromolecule orientations in thin films formed in cryo-EM
Yadav, S., & Vinothkumar, K. R. (2024) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798324005229 · Cited by 7
Metadata
- Authors
- Dandey, V. P., Budell, W. C., Wei, H., Bobe, D., Maruthi, K., Kopylov, M., Eng, E. T., Kahn, P. A., Hinshaw, J. E., Kundu, N., Nimigean, C. M., Fan, C., Sukomon, N., Darst, S. A., Saecker, R. M., Chen, J., Malone, B., Potter, C. S., & Carragher, B.
- Venue
- Nature Methods
- Published
- 2020-08-10
- Volume
- 17
- Issue
- 9
- Pages
- 897-900
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W3047834043
- Cited by
- 140
- References
- 1
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Time-resolved cryo-EM using Spotiton. https://app.cochat.ai/papers/10.1038/s41592-020-0925-6
- The paper
- Dandey, V. P., Budell, W. C., Wei, H., Bobe, D., Maruthi, K., Kopylov, M., Eng, E. T., Kahn, P. A., Hinshaw, J. E., Kundu, N., Nimigean, C. M., Fan, C., Sukomon, N., Darst, S. A., Saecker, R. M., Chen, J., Malone, B., Potter, C. S., & Carragher, B. (2020). Time-resolved cryo-EM using Spotiton. Nature Methods. https://doi.org/10.1038/s41592-020-0925-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.