The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Spectral entropy outperforms MS/MS dot product similarity for small-molecule compound identification
Open accessAbstract
Compound identification in small-molecule research, such as untargeted metabolomics or exposome research, relies on matching tandem mass spectrometry (MS/MS) spectra against experimental or in silico mass spectral libraries. Most software programs use dot product similarity scores. Here we introduce the concept of MS/MS spectral entropy to improve scoring results in MS/MS similarity searches via library matching. Entropy similarity outperformed 42 alternative similarity algorithms, including dot product similarity, when searching 434,287 spectra against the high-quality NIST20 library. Entropy similarity scores proved to be highly robust even when we added different levels of noise ions. When we applied entropy levels to 37,299 experimental spectra of natural products, false discovery rates of less than 10% were observed at entropy similarity score 0.75. Experimental human gut metabolome data were used to confirm that entropy similarity largely improved the accuracy of MS-based annotations in small-molecule research to false discovery rates below 10%, annotated new compounds and provided the basis to automatically flag poor-quality, noisy spectra. This manuscript proposes the use of spectral entropy similarity as a measure of similarity for small-molecule mass spectra and the use of a one-bond-difference approach for improving false discovery rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
Optimization and testing of mass spectral library search algorithms for compound identification
Stein, S. E., & Scott, D. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)87009-8 · Cited by 882
Cited by
Pang, Z., Lu, Y., Zhou, G., Hui, F., Xu, L., Viau, C., Spigelman, A. F., MacDonald, P. E., Wishart, D. S., Li, S., et al. (2024) · Nucleic Acids Research · doi:10.1093/nar/gkae253 · Cited by 2,291
Zhou, Z., Luo, M., Zhang, H., Yin, Y., Cai, Y., & Zhu, Z.-J. (2022) · Nature Communications · doi:10.1038/s41467-022-34537-6 · Cited by 339
MetaboAnalystR 4.0: a unified LC-MS workflow for global metabolomics
Pang, Z., Xu, L., Viau, C., Lu, Y., Salavati, R., Basu, N., & Xia, J. (2024) · Nature Communications · doi:10.1038/s41467-024-48009-6 · Cited by 284
Metadata
- Authors
- Li, Y., Kind, T., Folz, J., Vaniya, A., Mehta, S. S., & Fiehn, O.
- Venue
- Nature Methods
- Published
- 2021-12
- Volume
- 18
- Issue
- 12
- Pages
- 1524-1531
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W3216027541
- Cited by
- 222
- References
- 2
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral entropy outperforms MS/MS dot product similarity for small-molecule compound identification. https://app.cochat.ai/papers/10.1038/s41592-021-01331-z
- The paper
- Li, Y., Kind, T., Folz, J., Vaniya, A., Mehta, S. S., & Fiehn, O. (2021). Spectral entropy outperforms MS/MS dot product similarity for small-molecule compound identification. Nature Methods. https://doi.org/10.1038/s41592-021-01331-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.