Quadriwave lateral shearing interferometric microscopy with wideband sensitivity enhancement for quantitative phase imaging in real time
Open accessThe DOI matches its Crossref record.
Abstract
Real-time quantitative phase imaging has tremendous potential in investigating live biological specimens in vitro. Here we report on a wideband sensitivity-enhanced interferometric microscopy for quantitative phase imaging in real time by employing two quadriwave lateral shearing interferometers based on randomly encoded hybrid gratings with different lateral shears. Theoretical framework to analyze the measurement sensitivity is firstly proposed, from which the optimal lateral shear pair for sensitivity enhancement is also derived. To accelerate the phase retrieval algorithm for real-time visualization, we develop a fully vectorized path-independent differential leveling phase unwrapping algorithm ready for parallel computing, and the framerate for retrieving the phase from each pair of two 4 mega pixel interferograms is able to reach 47.85 frames per second. Experiment results demonstrate that the wideband sensitivity-enhanced interferometric microscopy is capable of eliminating all the periodical error caused by spectral leaking problem and reducing the temporal standard deviation to the half level compared with phase directly retrieved by the interferogram. Due to its high adaptability, the wideband sensitivity-enhanced interferometric microscopy is promising in retrofitting existing microscopes to quantitative phase microscopes with high measurement precision and real-time visualization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent progress in carbon-based materials for supercapacitor electrodes: a review
Wang, Y., Zhang, L., Hou, H., Xu, W., Duan, G., He, S., Liu, K., & Jiang, S. (2021) · Journal of Materials Science · doi:10.1007/s10853-020-05157-6 · Cited by 912
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
Synthesis, stabilization and applications of 2-dimensional 1T metallic MoS 2
Shi, S., Sun, Z., & Hu, Y. H. (2018) · Journal of Materials Chemistry A · doi:10.1039/c8ta08152b · Cited by 374
Recent progress in non-native nucleic acid modifications
McKenzie, L. K., El-Khoury, R., Thorpe, J. D., Damha, M. J., & Hollenstein, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01430c · Cited by 300
Advancing Frontiers in Bone Bioprinting
Ashammakhi, N., Hasan, A., Kaarela, O., Byambaa, B., Sheikhi, A., Gaharwar, A. K., & Khademhosseini, A. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801048 · Cited by 244
Metadata
- Authors
- Ling, T., Jiang, J., Zhang, R., & Yang, Y.
- Venue
- Scientific Reports
- Published
- 2017-01-31
- Volume
- 7
- Issue
- 1
- Pages
- 9-9
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2581341290
- Cited by
- 152
- References
- 0
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quadriwave lateral shearing interferometric microscopy with wideband sensitivity enhancement for quantitative phase imaging in real time. https://app.cochat.ai/papers/10.1038/s41598-017-00053-7
- The paper
- Ling, T., Jiang, J., Zhang, R., & Yang, Y. (2017). Quadriwave lateral shearing interferometric microscopy with wideband sensitivity enhancement for quantitative phase imaging in real time. Scientific Reports. https://doi.org/10.1038/s41598-017-00053-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.