Development of gold nanoparticle-aptamer-based LSPR sensing chips for the rapid detection of Salmonella typhimurium in pork meat
Open accessThe DOI matches its Crossref record.
Abstract
A non-labeled, portable plasmonic biosensor-based device was developed to enable the ultra-sensitive and selective detection of Salmonella typhimurium in pork meat samples. Specifically, a plasmonic sensor, using the self-assembly of gold nanoparticles (AuNPs) to achieve a regulated diameter of 20 nm for the AuNP monolayers, was used to conduct high-density deposition on a transparent substrate, which produced longitudinal wavelength extinction shifts via a localized surface plasmon resonance (LSPR) signal. The developed aptamers conjugated to the LSPR sensing chips revealed an ultra-sensitive upper limit of detection (LOD) of approximately 10 4 cfu/mL for S. typhimurium in pure culture under the optimal assay conditions, with a total analysis time of 30–35 min. When the LSPR sensing chips were applied on artificially contaminated pork meat samples, S. typhimurium in the spiked pork meat samples was also detected at an LOD of 1.0 × 10 4 cfu/mL. The developed method could detect S. typhimurium in spiked pork meat samples without a pre-enrichment step. Additionally, the LSPR sensing chips developed against S. typhimurium were not susceptible to any effect of the food matrix or background contaminant microflora. These findings confirmed that the developed gold nanoparticle-aptamer-based LSPR sensing chips could facilitate sensitive detection of S. typhimurium in food samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prospects of using nanotechnology for food preservation, safety, and security
Bajpai, V. K., Kamle, M., Shukla, S., Mahato, D. K., Chandra, P., Hwang, S. K., Kumar, P., Huh, Y. S., & Han, Y.-K. (2018) · Journal of Food and Drug Analysis · doi:10.1016/j.jfda.2018.06.011 · Cited by 463
Self-citationBiosensors for rapid detection of bacterial pathogens in water, food and environment
Nnachi, R. C., Sui, N., Ke, B., Luo, Z., Bhalla, N., He, D., & Yang, Z. (2022) · Environment International · doi:10.1016/j.envint.2022.107357 · Cited by 297
Portable and field-deployed surface plasmon resonance and plasmonic sensors
Masson, J.-F. (2020) · The Analyst · doi:10.1039/d0an00316f · Cited by 195
Detection of pathogenic bacteria via nanomaterials-modified aptasensors
Sharifi, S., Vahed, S. Z., Ahmadian, E., Dizaj, S. M., Eftekhari, A., Khalilov, R., Ahmadi, M., Hamidi-Asl, E., & Labib, M. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111933 · Cited by 170
One size does not fit all; practical, personal tailoring of the diet to NAFLD patients
Zelber‐Sagi, S., Grinshpan, L. S., Ivancovsky‐Wajcman, D., Goldenshluger, A., & Gepner, Y. (2022) · Liver International · doi:10.1111/liv.15335 · Cited by 49
Metadata
- Authors
- Oh, S. Y., Heo, N. S., Shukla, S., Cho, H.-J., Vilian, A. T. E., Kim, J., Lee, S. Y., Han, Y.-K., Yoo, S. M., & Huh, Y. S.
- Venue
- Scientific Reports
- Published
- 2017-08-31
- Volume
- 7
- Issue
- 1
- Pages
- 10130-10130
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2746793167
- Cited by
- 187
- References
- 0
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.