Abstract
The paradigm of molecular histopathology is shifting from a single-marker immunohistochemistry towards multiplexed detection of markers to better understand the complex pathological processes. However, there are no systems allowing multiplexed IHC (mIHC) with high-resolution whole-slide tissue imaging and analysis, yet providing feasible throughput for routine use. We present an mIHC platform combining fluorescent and chromogenic staining with automated whole-slide imaging and integrated whole-slide image analysis, enabling simultaneous detection of six protein markers and nuclei, and automatic quantification and classification of hundreds of thousands of cells in situ in formalin-fixed paraffin-embedded tissues. In the first proof-of-concept, we detected immune cells at cell-level resolution (n = 128,894 cells) in human prostate cancer, and analysed T cell subpopulations in different tumour compartments (epithelium vs. stroma). In the second proof-of-concept, we demonstrated an automatic classification of epithelial cell populations (n = 83,558) and glands (benign vs. cancer) in prostate cancer with simultaneous analysis of androgen receptor (AR) and alpha-methylacyl-CoA (AMACR) expression at cell-level resolution. We conclude that the open-source combination of 8-plex mIHC detection, whole-slide image acquisition and analysis provides a robust tool allowing quantitative, spatially resolved whole-slide tissue cytometry directly in formalin-fixed human tumour tissues for improved characterization of histology and the tumour microenvironment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398 · cited 1×
“To design our pipeline as generic as possible, we utilized automatic thresholding (Otsu 33 ) instead of manual thresholding.”
MethodSpeeded-Up Robust Features (SURF)
Bay, H., Ess, A., Tuytelaars, T., & Van Gool, L. (2008) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2007.09.014 · Cited by 13,557
Caselles, V., Kimmel, R., & Sapiro, G. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007979827043 · Cited by 5,244
Quantification of histochemical staining by color deconvolution.
Ruifrok, A. C. C., & Johnston, D. A. (2001) · PubMed · Cited by 2,568
Highly multiplexed imaging of tumor tissues with subcellular resolution by mass cytometry
Giesen, C., Wang, H. A. O., Schapiro, D., Zivanovic, N., Jacobs, A., Hattendorf, B., Schüffler, P. J., Grolimund, D., Buhmann, J. M., Brandt, S., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2869 · Cited by 1,951
Multiplexed ion beam imaging of human breast tumors
Angelo, M., Bendall, S. C., Finck, R., Hale, M. B., Hitzman, C., Borowsky, A. D., Levenson, R. M., Lowe, J. B., Liu, S. D., Zhao, S., et al. (2014) · Nature Medicine · doi:10.1038/nm.3488 · Cited by 1,108 · cited 2×
“The current state-of-the-art employ either fluorescence 1–9 or mass spectrometry 10–12 detection.”
BackgroundMethodKamentsky, L., Jones, T. R., Fraser, A., Bray, M.-A., Logan, D. J., Madden, K. L., Ljosa, V., Rueden, C., Eliceiri, K. W., & Carpenter, A. E. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr095 · Cited by 1,000
Catalyzed reporter deposition, a novel method of signal amplification application to immunoassays
Bobrow, M. N., Harris, T. D., Shaughnessy, K. J., & Litt, G. J. (1989) · Journal of Immunological Methods · doi:10.1016/0022-1759(89)90104-x · Cited by 769 · cited 1×
“As the detection of the first pair of primary antibodies is based on tyramide signal amplification (TSA) 18,21,22 followed by an inactivating heating step and additional pair of primary antibodies (see Supplementary Fig.”
BackgroundStack, E. C., Wang, C., Roman, K. A., & Hoyt, C. C. (2014) · Methods · doi:10.1016/j.ymeth.2014.08.016 · Cited by 768 · cited 2×
“This differs from the published methods utilizing TSA 6,8,9,22 , where a heating step is applied prior to every single primary antibody, hence making them slower and potentially compromising the tissue integrity.”
BackgroundMethodAutomated subcellular localization and quantification of protein expression in tissue microarrays
Camp, R. L., Chung, G. G., & Rimm, D. L. (2002) · Nature Medicine · doi:10.1038/nm791 · Cited by 764
Cited by
Digital pathology and artificial intelligence in translational medicine and clinical practice
Baxi, V., Edwards, R., Montalto, M., & Saha, S. (2022) · Modern Pathology · doi:10.1038/s41379-021-00919-2 · Cited by 592
Zlokovic, B. V., Gottesman, R. F., Bernstein, K. E., Seshadri, S., McKee, A., Snyder, H., Greenberg, S. M., Yaffe, K., Schaffer, C. B., Yuan, C., et al. (2020) · Alzheimer's & Dementia · doi:10.1002/alz.12157 · Cited by 232
Amgad, M., Stovgaard, E. S., Balslev, E., Thagaard, J., Chen, W., Dudgeon, S., Sharma, A., Kerner, J. K., Denkert, C., Yuan, Y., et al. (2020) · npj Breast Cancer · doi:10.1038/s41523-020-0154-2 · Cited by 171
“The speci fi c highlighting of TILs by IHC can improve algorithm speci fi city 47,48 , and enable characterization of TIL subpopulations that have potentially distinct prognostic or predictive roles 49,50 .”
Background
Metadata
- Authors
- Blom, S., Paavolainen, L., Bychkov, D., Turkki, R., Mäki-Teeri, P., Hemmes, A., Välimäki, K., Lundin, J., Kallioniemi, O., & Pellinen, T.
- Venue
- Scientific Reports
- Published
- 2017-11-14
- Volume
- 7
- Issue
- 1
- Pages
- 15580-15580
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2768059176
- Cited by
- 160
- References
- 36
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.