Very high density EEG elucidates spatiotemporal aspects of early visual processing
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Standard human EEG systems based on spatial Nyquist estimates suggest that 20–30 mm electrode spacing suffices to capture neural signals on the scalp, but recent studies posit that increasing sensor density can provide higher resolution neural information. Here, we compared “super-Nyquist” density EEG (“SND”) with Nyquist density (“ND”) arrays for assessing the spatiotemporal aspects of early visual processing. EEG was measured from 128 electrodes arranged over occipitotemporal brain regions (14 mm spacing) while participants viewed flickering checkerboard stimuli. Analyses compared SND with ND-equivalent subsets of the same electrodes. Frequency-tagged stimuli were classified more accurately with SND than ND arrays in both the time and the frequency domains. Representational similarity analysis revealed that a computational model of V1 correlated more highly with the SND than the ND array. Overall, SND EEG captured more neural information from visual cortex, arguing for increased development of this approach in basic and translational neuroscience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“EEG data analysis was performed offline using EEGlab (Delorme & Makeig, 2004).”
MethodLakens, D. (2013) · Frontiers in Psychology · doi:10.3389/fpsyg.2013.00863 · Cited by 10,303 · cited 1×
“Effect sizes were calculated for all statistical comparisons; generalised eta-squared values ( η g2 ) were calculated for ANOVA results, and Hedges’ g av was calculated for paired samples t -tests (Bakeman, 2005; Lakens, 2013). not certified by peer review) is the author/funder.”
MethodRepresentational similarity analysis-connecting the branches of systems neuroscience
Kriegeskorte, N. (2008) · Frontiers in Systems Neuroscience · doi:10.3389/neuro.06.004.2008 · Cited by 3,355
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
Recommended effect size statistics for repeated measures designs
Bakeman, R. (2005) · Behavior Research Methods · doi:10.3758/bf03192707 · Cited by 1,809
The PREP pipeline: standardized preprocessing for large-scale EEG analysis
Bigdely-Shamlo, N., Mullen, T., Kothe, C., Su, K.-M., & Robbins, K. A. (2015) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2015.00016 · Cited by 1,351
Engel, S. A., Rumelhart, D. E., Wandell, B. A., Lee, A. T., Glover, G. H., Chichilnisky, E.-J., & Shadlen, M. N. (1994) · Nature · doi:10.1038/369525a0 · Cited by 990
A feedforward architecture accounts for rapid categorization
Serre, T., Oliva, A., & Poggio, T. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700622104 · Cited by 918
Cited by
COVID-19 and multiorgan failure: A narrative review on potential mechanisms
Mokhtari, T., Hassani, F., Ghaffari, N., Ebrahimi, B., Yarahmadi, A., & Hassanzadeh, G. (2020) · Journal of Molecular Histology · doi:10.1007/s10735-020-09915-3 · Cited by 439
He, M., Xiong, X., Wang, L., Hou, D., Bolan, N. S., Ok, Y. S., Rinklebe, J., & Tsang, D. C. W. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125378 · Cited by 294
McNamara, J., Townsend, M. L., & Herbert, J. S. (2019) · PLOS ONE · doi:10.1371/journal.pone.0220032 · Cited by 222
Li, M., Virguez, E., Shan, R., Tian, J., Gao, S., & Patiño-Echeverri, D. (2022) · Applied Energy · doi:10.1016/j.apenergy.2021.117996 · Cited by 183
MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation
Driscoll, N., Erickson, B., Murphy, B. B., Richardson, A. G., Robbins, G., Apollo, N. V., Mentzelopoulos, G., Mathis, T., Hantanasirisakul, K., Bagga, P., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abf8629 · Cited by 180
The cognition of ‘nuisance’ species
Barrett, L. P., Stanton, L. A., & Benson-Amram, S. (2019) · Animal Behaviour · doi:10.1016/j.anbehav.2018.05.005 · Cited by 166
Jogawat, A., Yadav, B., Chhaya, & Narayan, O. P. (2021) · Physiologia Plantarum · doi:10.1111/ppl.13370 · Cited by 140
Impact of plasma reactive species on the structure and functionality of pea protein isolate
Bu, F., Nayak, G., Bruggeman, P., Annor, G., & Ismail, B. P. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2021.131135 · Cited by 105
Banellis, L., & Cruse, D. (2020) · Cerebral Cortex Communications · doi:10.1093/texcom/tgaa060 · Cited by 44
Metadata
- Authors
- Robinson, A. K., Venkatesh, P., Boring, M. J., Tarr, M. J., Grover, P., & Behrmann, M.
- Venue
- Scientific Reports
- Published
- 2017-11-24
- Volume
- 7
- Issue
- 1
- Pages
- 16248-16248
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2951463227
- Cited by
- 302
- References
- 28
- FWCI
- 20.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.