Accurate and fiducial-marker-free correction for three-dimensional chromatic shift in biological fluorescence microscopy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Correction of chromatic shift is necessary for precise registration of multicolor fluorescence images of biological specimens. New emerging technologies in fluorescence microscopy with increasing spatial resolution and penetration depth have prompted the need for more accurate methods to correct chromatic aberration. However, the amount of chromatic shift of the region of interest in biological samples often deviates from the theoretical prediction because of unknown dispersion in the biological samples. To measure and correct chromatic shift in biological samples, we developed a quadrisection phase correlation approach to computationally calculate translation, rotation, and magnification from reference images. Furthermore, to account for local chromatic shifts, images are split into smaller elements, for which the phase correlation between channels is measured individually and corrected accordingly. We implemented this method in an easy-to-use open-source software package, called Chromagnon, that is able to correct shifts with a 3D accuracy of approximately 15 nm. Applying this software, we quantified the level of uncertainty in chromatic shift correction, depending on the imaging modality used, and for different existing calibration methods, along with the proposed one. Finally, we provide guidelines to choose the optimal chromatic shift registration method for any given situation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
Cited by
Watts, A. J. B., Keller, K. H., Lerner, G., Rosales, I., Collins, A. B., Sekulic, M., Waikar, S. S., Chandraker, A., Riella, L. V., Alexander, M. P., et al. (2022) · Journal of the American Society of Nephrology · doi:10.1681/asn.2021060794 · Cited by 397
BigStitcher: reconstructing high-resolution image datasets of cleared and expanded samples
Hörl, D., Rojas Rusak, F., Preusser, F., Tillberg, P., Randel, N., Chhetri, R. K., Cardona, A., Keller, P. J., Harz, H., Leonhardt, H., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0501-0 · Cited by 383
Miron, E., Oldenkamp, R., Brown, J. M., Pinto, D. M. S., Xu, C. S., Faria, A. R., Shaban, H. A., Rhodes, J. D. P., Innocent, C., de Ornellas, S., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba8811 · Cited by 200
Self-citationTracking and interpreting long-range chromatin interactions with super-resolution live-cell imaging
Brandão, H. B., Gabriele, M., & Hansen, A. S. (2021) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2020.11.002 · Cited by 77
Uniform dynamics of cohesin-mediated loop extrusion in living human cells
Sabaté, T., Lelandais, B., Robert, M.-C., Szalay, M., Tinevez, J.-Y., Bertrand, E., & Zimmer, C. (2025) · Nature Genetics · doi:10.1038/s41588-025-02406-9 · Cited by 32
Metadata
- Authors
- Matsuda, A., Schermelleh, L., Hirano, Y., Haraguchi, T., & Hiraoka, Y.
- Venue
- Scientific Reports
- Published
- 2018-05-15
- Volume
- 8
- Issue
- 1
- Pages
- 7583-7583
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2804772367
- Cited by
- 70
- References
- 1
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate and fiducial-marker-free correction for three-dimensional chromatic shift in biological fluorescence microscopy. https://app.cochat.ai/papers/10.1038/s41598-018-25922-7
- The paper
- Matsuda, A., Schermelleh, L., Hirano, Y., Haraguchi, T., & Hiraoka, Y. (2018). Accurate and fiducial-marker-free correction for three-dimensional chromatic shift in biological fluorescence microscopy. Scientific Reports. https://doi.org/10.1038/s41598-018-25922-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.