Optimization of Optomotor Response-based Visual Function Assessment in Mice
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Optomotor response/reflex (OMR) assays are emerging as a powerful and versatile tool for phenotypic study and new drug discovery for eye and brain disorders. Yet efficient OMR assessment for visual performance in mice remains a challenge. Existing OMR testing devices for mice require a lengthy procedure and may be subject to bias due to use of artificial criteria. We developed an optimized staircase protocol that utilizes mouse head pausing behavior as a novel indicator for the absence of OMR, to allow rapid and unambiguous vision assessment. It provided a highly sensitive and reliable method that can be easily implemented into automated or manual OMR systems to allow quick and unbiased assessment for visual acuity and contrast sensitivity in mice. The sensitivity and quantitative capacity of the protocol were validated using wild type mice and an inherited mouse model of retinal degeneration – mice carrying rhodopsin deficiency and exhibiting progressive loss of photoreceptors. Our OMR system with this protocol was capable of detecting progressive visual function decline that was closely correlated with the loss of photoreceptors in rhodopsin deficient mice. It provides significant advances over the existing methods in the currently available OMR devices in terms of sensitivity, accuracy and efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Retinopathy induced in mice by targeted disruption of the rhodopsin gene
Humphries, M. M., Rancourt, D., Farrar, G. J., Kenna, P., Hazel, M., Bush, R. A., Sieving, P. A., Sheils, D. M., Creighton, P., Erven, A., et al. (1997) · Nature Genetics · doi:10.1038/ng0297-216 · Cited by 529
The visual physiology of the wild type mouse determined with pattern VEPs
Porciatti, V., Pizzorusso, T., & Maffei, L. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00022-x · Cited by 202
Cited by
Kist, A. M., & Portugues, R. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.09.024 · Cited by 55
Pan, L., Cho, K.-S., Wei, X., Xu, F., Lennikov, A., Hu, G., Tang, J., Guo, S., Chen, J., Kriukov, E., et al. (2023) · Cell Reports · doi:10.1016/j.celrep.2023.112889 · Cited by 52
“56,57 As expected, IOP elevation induced significant reductions of pSTR amplitudes (Figure 6C) and loss of visual acuity (VA) and contrast sensitivity (CS), assessed using optomotor reflex assays 58 (Figures 6D and 6E) in the PBS-treated group.”
Self-citationGene dosage manipulation alleviates manifestations of hereditary PAX6 haploinsufficiency in mice
Rabiee, B., Anwar, K. N., Shen, X., Putra, I., Liu, M., Jung, R., Afsharkhamseh, N., Rosenblatt, M. I., Fishman, G. A., Liu, X., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaz4894 · Cited by 28
“This test is based on the optokinetic response, which is used to measure visual function clinically in infants and experimentally in animal models (29, 30).”
Methodσ2R/TMEM97 in retinal ganglion cell degeneration
Wang, H., Peng, Z., Li, Y., Sahn, J. J., Hodges, T. R., Chou, T.-H., Liu, Q., Zhou, X., Jiao, S., Porciatti, V., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-24537-3 · Cited by 13
Metadata
- Authors
- Shi, C., Yuan, X., Chang, K., Cho, K.-S., Xie, X. S., Chen, D. F., & Luo, G.
- Venue
- Scientific Reports
- Published
- 2018-06-26
- Volume
- 8
- Issue
- 1
- Pages
- 9708-9708
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2809033030
- Cited by
- 40
- References
- 2
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of Optomotor Response-based Visual Function Assessment in Mice. https://app.cochat.ai/papers/10.1038/s41598-018-27329-w
- The paper
- Shi, C., Yuan, X., Chang, K., Cho, K.-S., Xie, X. S., Chen, D. F., & Luo, G. (2018). Optimization of Optomotor Response-based Visual Function Assessment in Mice. Scientific Reports. https://doi.org/10.1038/s41598-018-27329-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.