Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Evaluation of Oxford Nanopore’s MinION Sequencing Device for Microbial Whole Genome Sequencing Applications

Open access

Abstract

The MinION sequencer (Oxford Nanopore Technologies) is a paradigm shifting device allowing rapid, real time long read sequencing of nucleic acids. Yet external benchmarking of this technologies’ capabilities has not been extensively reported, nor has thorough evaluation of its utility for field-based analysis with sub-optimal sample types been described. The aim of this study was to evaluate the capability of the MinION sequencer for bacterial genomic and metagenomic applications, with specific emphasis placed on the quality, yield, and accuracy of generated sequence data. Two independent laboratories at the National Microbiology Laboratory (Public Health Agency of Canada), sequenced a set of microbes in replicate, using the currently available flowcells, sequencing chemistries, and software available at the time of the experiment. Overall sequencing yield and quality improved through the course of this set of experiments. Sequencing alignment accuracy was high reaching 97% for all 2D experiments, though was slightly lower for 1D sequencing (94%). 1D sequencing provided much longer sequences than 2D. Both sequencing chemistries performed equally well in constructing genomic assemblies. There was evidence of barcode cross-over using both the native and PCR barcoding methods. Despite the sub-optimal nature of samples sequenced in the field, sequences attributable to B. anthracis the target organism used in this scenario, could none-the-less be detected. Together, this report showcases the rapid advancement in this technology and its utility in the context of genomic sequencing of microbial isolates of importance to public health.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-018-29334-5

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 DNA yield in number of reads which were analyzed further (pass) and reads which were excluded based on either internal Epi2Me filtering parameters or inability to demultiplex (Fail), on each of the flowcells tested. FAB-R9.4; FAF- R9.4 SpotOn. The first set of samples were assessed using Epi2Me, the second set by Albacore, and the third by MinKNOW direct basecalling. *This sample had a second top up run added 1 hour following the commencement of sequencing.
Figure 1 DNA yield in number of reads which were analyzed further (pass) and reads which were excluded based on either internal Epi2Me filtering parameters or inability to demultiplex (Fail), on each of the flowcells tested. FAB-R9.4; FAF- R9.4 SpotOn. The first set of samples were assessed using Epi2Me, the second set by Albacore, and the third by MinKNOW direct basecalling. *This sample had a second top up run added 1 hour following the commencement of sequencing.CC BY · PubMed Central
Figure 2 Mean quality per 2000 base pair window across each of the MinION runs included in this analysis calculated using fastqc32. Lines extend further as the length of the read increases. Earlier runs were characterized by both shorter reads, and lower quality output data generated. L1-2D-FAB29623 is broken into pre and post, referring to read quality before and after the wash buffer was applied.
Figure 2 Mean quality per 2000 base pair window across each of the MinION runs included in this analysis calculated using fastqc32. Lines extend further as the length of the read increases. Earlier runs were characterized by both shorter reads, and lower quality output data generated. L1-2D-FAB29623 is broken into pre and post, referring to read quality before and after the wash buffer was applied.CC BY · PubMed Central
Figure 3 Boxplot depicting the mean genomic coverage obtained across each of the reference genomes included in this analysis. Sequenced organisms and the corresponding average levels of coverage for each are coloured as described.
Figure 3 Boxplot depicting the mean genomic coverage obtained across each of the reference genomes included in this analysis. Sequenced organisms and the corresponding average levels of coverage for each are coloured as described.CC BY · PubMed Central
Figure 4 Error characteristics of data generated in various sequencing runs included in this analysis. (A) Proportion of bases accurately matching mapped segment of the reference. (B) Insertions per 100 aligned bases. (C) Deletions per 100 aligned bases. (D) Substitutions per 100 aligned bases.
Figure 4 Error characteristics of data generated in various sequencing runs included in this analysis. (A) Proportion of bases accurately matching mapped segment of the reference. (B) Insertions per 100 aligned bases. (C) Deletions per 100 aligned bases. (D) Substitutions per 100 aligned bases.CC BY · PubMed Central
Figure 5 Assembly characteristics of contigs generated following subsampling of fastq reads generated with 1D sequencing and native barcoding. Dashed line is the reference genome size reported by NCBI.
Figure 5 Assembly characteristics of contigs generated following subsampling of fastq reads generated with 1D sequencing and native barcoding. Dashed line is the reference genome size reported by NCBI.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Research works printed but not linked: 1

  1. Multiple contributors. Oxford Nanopore Community. Available at: community.nanoporetech.com. (Accessed: 12th March 2018) (2018).

Cited by

See all 322

Metadata

Authors
Tyler, A. D., Mataseje, L., Urfano, C. J., Schmidt, L., Antonation, K. S., Mulvey, M. R., & Corbett, C. R.
Affiliations
Public Health Agency of Canada (CA)
Corresponding author
Tyler, Andrea D.
Venue
Scientific Reports
Published
2018-07-19
Volume
8
Issue
1
Pages
10931-10931
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2884978946
Cited by
294
References
29
Citations by year
2026: 24 · 2025: 19 · 2024: 33 · 2023: 22 · 2022: 46 · 2021: 48 · 2020: 55 · 2019: 44 · 2018: 3
FWCI
13.34
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • Canadian Safety and Security Program
  • Genomics Research and Development Initiative
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
  • Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
  • Physical Sciences › Engineering › Biomedical Engineering › Nanopore and Nanochannel Transport Studies
Keywords
Oxford Nanopore MinION, long-read sequencing, bacterial whole-genome sequencing, metagenomics, sequencing accuracy, genome assembly, Bacillus anthracis, public health microbiology
MeSH terms
Whole Genome Sequencing, Bacillus anthracis, Genome, Bacterial, Metagenomics, Nanopores, High-Throughput Nucleotide Sequencing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Oxford Nanopore’s MinION Sequencing Device for Microbial Whole Genome Sequencing Applications. https://app.cochat.ai/papers/10.1038/s41598-018-29334-5
The paper
Tyler, A. D., Mataseje, L., Urfano, C. J., Schmidt, L., Antonation, K. S., Mulvey, M. R., & Corbett, C. R. (2018). Evaluation of Oxford Nanopore’s MinION Sequencing Device for Microbial Whole Genome Sequencing Applications. Scientific Reports. https://doi.org/10.1038/s41598-018-29334-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.