The DOI matches its Crossref record; 56 of the 57 references it cites were found in a registry or an index.
Performance of Deep Learning Architectures and Transfer Learning for Detecting Glaucomatous Optic Neuropathy in Fundus Photographs
Open accessAbstract
The ability of deep learning architectures to identify glaucomatous optic neuropathy (GON) in fundus photographs was evaluated. A large database of fundus photographs (n = 14,822) from a racially and ethnically diverse group of individuals (over 33% of African descent) was evaluated by expert reviewers and classified as GON or healthy. Several deep learning architectures and the impact of transfer learning were evaluated. The best performing model achieved an overall area under receiver operating characteristic (AUC) of 0.91 in distinguishing GON eyes from healthy eyes. It also achieved an AUC of 0.97 for identifying GON eyes with moderate-to-severe functional loss and 0.89 for GON eyes with mild functional loss. A sensitivity of 88% at a set 95% specificity was achieved in detecting moderate-to-severe GON. In all cases, transfer improved performance and reduced training time. Model visualizations indicate that these deep learning models relied on, in part, anatomical features in the inferior and superior regions of the optic disc, areas commonly used by clinicians to diagnose GON. The results suggest that deep learning-based assessment of fundus images could be useful in clinical decision support systems and in the automation of large-scale glaucoma detection and screening programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Only eight studies14–21 used prospectively collected data”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 1×
“ResNet incorporates residual layers to help aid the model achieve convergence during training of very deep networks such as these 51 .”
MethodVery Deep Convolutional Networks for Large-Scale Image Recognition
Simonyan, K., & Zisserman, A. (2014) · arXiv · doi:10.48550/arxiv.1409.1556 · Cited by 114,148 · cited 4×
“The performance of the ResNet50 architecture was significantly better than that of the VGG16 and Inception architectures.”
MethodInfluentialLeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Going deeper with convolutions
Szegedy, C., Liu, W., Jia, Y., Sermanet, P., Reed, S., Anguelov, D., Erhan, D., Vanhoucke, V., & Rabinovich, A. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298594 · Cited by 48,562
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380 · cited 1×
“In all transfer learning cases, models were initially trained using the ImageNet database 36 .”
MethodVisualizing and understanding convolutional networks
Zeiler, M. D., & Fergus, R. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10590-1_53 · Cited by 15,839
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
(2010) · Cited by 14,134
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
Caffe: Convolutional Architecture for Fast Feature Embedding
Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., & Darrell, T. (2014) · Proceedings of the 22nd ACM international conference on Multimedia · doi:10.1145/2647868.2654889 · Cited by 11,077
Research works printed but not linked: 1
- Baker, B., Gupta, O., Naik, N. & Raskar, R. Designing Neural Network Architectures Using Reinforcement Learning. Proc. 5th Int. Conf. Learn. Represent. 1–18 (2017).
Cited by
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
Orlando, J. I., Fu, H., Barbosa Breda, J., van Keer, K., Bathula, D. R., Diaz-Pinto, A., Fang, R., Heng, P.-A., Kim, J., Lee, J., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101570 · Cited by 855
“laucoma classication uses receiver-operating characteristic (ROC) curves (Davis and Goadrich, 2006) for evaluation, including the area under the curve (AUC) as a summary value (Chen et al., 2015a,b; Christopher et al., 2018; Fu et al., 2018; Gomez-Valverde et al., 2019; Orlando et al., 2017b; Li et al., 2018a,b; Liu e…”
InfluentialA scoping review of transfer learning research on medical image analysis using ImageNet
Morid, M. A., Borjali, A., & Del Fiol, G. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104115 · Cited by 508
Thapa, C., & Camtepe, S. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104130 · Cited by 393
“A trained model on the ImageNet [169] database has been reused to train fundus images for the detection of Glaucomatous Optic Neuropathy with higher performance and faster convergence [172].”
MethodThe Application of Deep Learning in Cancer Prognosis Prediction
Zhu, W., Xie, L., Han, J., & Guo, X. (2020) · Cancers · doi:10.3390/cancers12030603 · Cited by 380
Metadata
- Authors
- Christopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M.
- Affiliations
- University of California San Diego (US)
- University of Alabama at Birmingham (US)
- Columbia University Irving Medical Center (US)
- Corresponding author
- Zangwill, Linda M.
- ORCID
- Venue
- Scientific Reports
- Published
- 2018-11-12
- Volume
- 8
- Issue
- 1
- Pages
- 16685-16685
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6232132
- OpenAlex
- W2899951262
- Cited by
- 328
- References
- 57
- Citations by year
- 2026: 21 · 2025: 33 · 2024: 30 · 2023: 43 · 2022: 68 · 2021: 64 · 2020: 44 · 2019: 23
- FWCI
- 22.59
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Columbia Academic Commons (Columbia University)
- Funders
- EyeSight Foundation of Alabama (EY11008, EY021818)
- Research to Prevent Blindness (T32EY026590, P30EY022589, EY022039, EY021818, EY11008, EY022589)
- Valeant Pharmaceuticals International
- Aerie Pharmaceuticals
- Carl Zeiss Meditec AG
- Heidelberg Engineering
- Genentech (EY11008, EY021818)
- Allergan (EY11008, EY021818)
- National Eye Institute (EY022589, EY029058, EY027945, EY 11008, R21EY027945, R01EY022039, R01EY023704, EY026590, R01EY029058, R01EY019869, EY022039, R01EY021818, R01EY011008, EY023704, R01EY026574, EY021818, R01EY027510, T32EY026590, P30EY022589)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
- Keywords
- glaucomatous optic neuropathy, fundus images, deep learning, transfer learning, glaucoma detection, optic nerve head, clinical decision support, automated screening, model interpretability
- MeSH terms
- Deep Learning, Glaucoma, Humans, Optic Nerve Diseases
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of Deep Learning Architectures and Transfer Learning for Detecting Glaucomatous Optic Neuropathy in Fundus Photographs. https://app.cochat.ai/papers/10.1038/s41598-018-35044-9
- The paper
- Christopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018). Performance of Deep Learning Architectures and Transfer Learning for Detecting Glaucomatous Optic Neuropathy in Fundus Photographs. Scientific Reports. https://doi.org/10.1038/s41598-018-35044-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.