Diagnostic value of digital clock drawing test in comparison with CERAD neuropsychological battery total score for discrimination of patients in the early course of Alzheimer’s disease from healthy individuals
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The early detection of cognitive impairment or dementia is in the focus of current research as the amount of cognitively impaired individuals will rise intensely in the next decades due to aging population worldwide. Currently available diagnostic tools to detect mild cognitive impairment (MCI) or dementia are time-consuming, invasive or expensive and not suitable for wide application as required by the high number of people at risk. Thus, a fast, simple and sensitive test is urgently needed to enable an accurate detection of people with cognitive dysfunction and dementia in the earlier stages to initiate specific diagnostic and therapeutic interventions. We examined digital Clock Drawing Test (dCDT) kinematics for their clinical utility in differentiating patients with amnestic MCI (aMCI) or mild Alzheimer’s dementia (mAD) from healthy controls (HCs) and compared it with the diagnostic value of the Consortium to Establish a Registry for Alzheimer’s Disease (CERAD) neuropsychological battery total score. Data of 381 participants (138 patients with aMCI, 106 patients with mAD and 137 HCs) was analyzed in the present study. All participants performed the clock drawing test (CDT) on a tablet computer and underwent the CERAD test battery and depression screening. CERAD total scores were calculated by subtest summation, excluding MMSE scores. All tablet variables (i.e. time in air, time on surface, total time, velocity, pressure, pressure/velocity relation, strokes per minute, time not painting, pen-up stroke length, pen-up/pen-down relation, and CDT score) during dCDT performance were entered in a forward stepwise logistic regression model to assess, which parameters best discriminated between aMCI or mAD and HC. Receiver operating characteristics (ROC) curves were constructed to visualize the specificity in relation to the sensitivity of dCDT variables against CERAD total scores in categorizing the diagnostic groups. dCDT variables provided a slightly better diagnostic accuracy of 81.5% for discrimination of aMCI from HCs than using CERAD total score (accuracy 77.5%). In aMCI patients with normal CDT scores, both dCDT (accuracy 78.0%) and CERAD total scores (accuracy 76.0%) were equally accurate in discriminating against HCs. Finally, in differentiating patients with mAD from healthy individuals, accuracy of both dCDT (93.0%) and CERAD total scores (92.3%) was excellent. Our findings suggest that dCDT is a suitable screening tool to identify early cognitive dysfunction. Its performance is comparable with the time-consuming established psychometric measure (CERAD test battery).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kok, J. S., Berg, I. J., & Scherder, E. J. A. (2013) · Dementia and Geriatric Cognitive Disorders Extra · doi:10.1159/000353441 · Cited by 20,589
Forecasting the global burden of Alzheimer's disease
Brookmeyer, R., Johnson, E., Ziegler‐Graham, K., & Arrighi, H. M. (2007) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2007.04.381 · Cited by 3,370
Alzheimer's Disease Neuroimaging Initiative (ADNI)
Petersen, R. C., Aisen, P. S., Beckett, L. A., Donohue, M. C., Gamst, A. C., Harvey, D. J., Jack, C. R., Jagust, W. J., Shaw, L. M., Toga, A. W., et al. (2010) · Neurology · doi:10.1212/wnl.0b013e3181cb3e25 · Cited by 2,572
Petersen, R. C., Stevens, J. C., Ganguli, M., Tangalos, E. G., Cummings, J. L., & DeKosky, S. T. (2001) · Neurology · doi:10.1212/wnl.56.9.1133 · Cited by 2,065
Welsh, K. A., Butters, N., Mohs, R. C., Beekly, D., Edland, S., Fillenbaum, G., & Heyman, A. (1994) · Neurology · doi:10.1212/wnl.44.4.609 · Cited by 951
A total score for the CERAD neuropsychological battery
Chandler, M. J., Lacritz, L. H., Hynan, L. S., Barnard, H. D., Allen, G., Deschner, M., Weiner, M. F., & Cullum, C. M. (2005) · Neurology · doi:10.1212/01.wnl.0000167607.63000.38 · Cited by 387
Autonomous unobtrusive detection of mild cognitive impairment in older adults
Akl, A., Taati, B., & Mihailidis, A. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2389149 · Cited by 126
Cited by
Alzheimer's disease digital biomarkers multidimensional landscape and AI model scoping review
Qi, W., Zhu, X., Wang, B., Shi, Y., Dong, C., Shen, S., Li, J., Zhang, K., He, Y., Zhao, M., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01640-z · Cited by 78
“Among the six manual biomarker studies 27,57,74,77,78 , fi ve studies reported ACC greater than 0.9 57,74,77 – 79 , while one study reported an ACC of 0.76 27 .”
InfluentialChan, J. Y. C., Bat, B. K. K., Wong, A., Chan, T. K., Huo, Z., Yip, B. H. K., Kowk, T. C. Y., & Tsoi, K. K. F. (2022) · Neuropsychology Review · doi:10.1007/s11065-021-09523-2 · Cited by 43
Yuan, J., Au, R., Karjadi, C., Ang, T. F., Devine, S., Auerbach, S., DeCarli, C., Libon, D. J., Mez, J., & Lin, H. (2022) · Journal of Medical Internet Research · doi:10.2196/34513 · Cited by 22
Metadata
- Authors
- Müller, S., Herde, L., Preische, O., Zeller, A., Heymann, P., Robens, S., Elbing, U., & Laske, C.
- Venue
- Scientific Reports
- Published
- 2019-03-05
- Volume
- 9
- Issue
- 1
- Pages
- 3543-3543
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2920483777
- Cited by
- 85
- References
- 7
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic value of digital clock drawing test in comparison with CERAD neuropsychological battery total score for discrimination of patients in the early course of Alzheimer’s disease from healthy individuals. https://app.cochat.ai/papers/10.1038/s41598-019-40010-0
- The paper
- Müller, S., Herde, L., Preische, O., Zeller, A., Heymann, P., Robens, S., Elbing, U., & Laske, C. (2019). Diagnostic value of digital clock drawing test in comparison with CERAD neuropsychological battery total score for discrimination of patients in the early course of Alzheimer’s disease from healthy individuals. Scientific Reports. https://doi.org/10.1038/s41598-019-40010-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.