Poly-L-Lysine functionalised MWCNT-rGO nanosheets based 3-d hybrid structure for femtomolar level cholesterol detection using cantilever based sensing platform
Open accessThe DOI matches its Crossref record.
Abstract
In this work we have developed a novel rGO-MWCNT (reduced graphene oxide-multiwalled carbon nanotube) nanocomposite material with Poly-L-Lysine functionalization which can be used for detection of biomolecules with enhanced sensitivity. The reduced GO sheets are found to play a major role as a connector and helps in the assembly of bundles of carbon nanotubes (CNTs) which may sometime play a role of upstanding nanostructures. The overall composite structure is further fully functionalized resulting in an overall high density of amino groups that can be used to capture biomolecules. The sensitivity of the as synthesized film is tested by the oxidation of cholesterol through cholesterol oxidase enzyme that is biochemically immobilized over these composite films. The test for the immobilization density of the novel films are carried out by mounting these films on sensitive thin section static micro/nano-cantilever platforms. The platforms have capability to measure cholesterol traces in blood upto an extent of 100 femto molar through deflection /bending of the cantilevers due to surface reaction. The films developed show a promise of high immobilization density which is further confirmed through fluorescence studies using FITC labeling of functionalized MWCNT-PLL and rGO-PLL films respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Anzar, N., Hasan, R., Tyagi, M., Yadav, N., & Narang, J. (2020) · Sensors International · doi:10.1016/j.sintl.2020.100003 · Cited by 634
Papini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90
Bhattacharjee, S., Kashyap, R., Goodwill, A. M., O'Brien, B. A., Rapp, B., Oishi, K., Desmond, J. E., & Chen, S. H. A. (2022) · Brain Stimulation · doi:10.1016/j.brs.2021.11.018 · Cited by 80
Fayed, B., Jayakumar, M. N., & Soliman, S. S. M. (2021) · Medical Mycology · doi:10.1093/mmy/myab059 · Cited by 41
Metadata
- Authors
- Basu, A. K., Sah, A. N., Pradhan, A., & Bhattacharya, S.
- Venue
- Scientific Reports
- Published
- 2019-03-06
- Volume
- 9
- Issue
- 1
- Pages
- 3686-3686
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2918575422
- Cited by
- 134
- References
- 0
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poly-L-Lysine functionalised MWCNT-rGO nanosheets based 3-d hybrid structure for femtomolar level cholesterol detection using cantilever based sensing platform. https://app.cochat.ai/papers/10.1038/s41598-019-40259-5
- The paper
- Basu, A. K., Sah, A. N., Pradhan, A., & Bhattacharya, S. (2019). Poly-L-Lysine functionalised MWCNT-rGO nanosheets based 3-d hybrid structure for femtomolar level cholesterol detection using cantilever based sensing platform. Scientific Reports. https://doi.org/10.1038/s41598-019-40259-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.