Inter- and intra-researcher reproducibility of heart rate variability parameters in three human cohorts
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV) is a valid and non-invasive indicator of cardiac autonomic nervous system functioning. Short-term HRV recordings (e.g., 10 min long) produce data that usually is manually processed. Researcher subjective decision-making on data processing could produce inter- or intra-researcher differences whose magnitude has not been previously quantified in three independent human cohorts. This study examines the inter- and intra-researcher reproducibility of HRV parameters (i.e., the influence of R–R interval selection by different researchers and by the same researcher in different moments on the quantification of HRV parameters, respectively) derived from short-term recordings in a cohort of children with overweight/obesity, young adults and middle-age adults. Participants were recruited from 3 different studies: 107 children (10.03 ± 1.13 years, 58% male), 132 young adults (22.22 ± 2.20 years, 33% males) and 73 middle-aged adults (53.62 ± 5.18 years, 48% males). HRV was measured using a Polar RS800CX heart rate monitor. The intraclass correlation coefficient (ICC) ranged from 0.703 to 0.989 and from 0.950 to 0.998 for inter-and intra-researcher reproducibility, respectively. Limits of agreement for HRV parameters were higher for the inter-researcher processing compared with the intra-researcher processing. On average, the intra-researcher differences were 31%, 62%, and 80% smaller than the inter-researchers differences based on Coefficient of Variation in children, young and middle-aged adults, respectively. Our study provides the quantification of the inter-researcher and intra-researcher differences in three independent human cohorts, which could elicit some clinical relevant differences for HRV parameters. Based on our findings, we recommend the HRV data signal processing to be performed always by the same trained researcher and we postulate a development of algorithms for an automatic ECG selection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“there are inconsistencies regarding the reproducibility of HRV measures in a variety of unrelated populations (64–66).”
From Alterations in Heart Rate Variability Associated With Irritable Bowel Syndrome or Inflammatory Bowel Disease: A Systematic Review and Meta-Analysis (2021) · cites this paper as [66]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Kubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720
Laborde, S., Mosley, E., & Thayer, J. F. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2017.00213 · Cited by 2,336
Shaffer, F., McCraty, R., & Zerr, C. L. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01040 · Cited by 1,866
The LF/HF ratio does not accurately measure cardiac sympatho-vagal balance
Billman, G. E. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00026 · Cited by 1,401
The role of vagal function in the risk for cardiovascular disease and mortality
Thayer, J. F., & Lane, R. D. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2005.11.013 · Cited by 1,033
Cited by
The effect of age on the heart rate variability of healthy subjects
Garavaglia, L., Gulich, D., Defeo, M. M., Mailland, J. T., & Irurzun, I. M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0255894 · Cited by 108
Besson, C., Baggish, A. L., Monteventi, P., Schmitt, L., Stucky, F., & Grémeaux, V. (2025) · Scientific Reports · doi:10.1038/s41598-025-89892-3 · Cited by 89
Short-term heart rate variability in resting conditions: methodological considerations
Plaza‐Florido, A., Sacha, J., & Alcántara, J. M. A. (2021) · Kardiologia Polska · doi:10.33963/kp.a2021.0054 · Cited by 51
“Another methodological example which has a direct impact on the quantification of the HRV derived parameters is the researcher [6].”
BackgroundMethodResultInfluentialSelf-citationSadowski, A., Dunlap, C., Lacombe, A., & Hanes, D. (2021) · Clinical and Translational Gastroenterology · doi:10.14309/ctg.0000000000000275 · Cited by 45
Plaza‐Florido, A., Alcántara, J. M. A., Amaro‐Gahete, F. J., Sacha, J., & Ortega, F. B. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01673-9 · Cited by 30
“From the obtained data, the best 5-min period was manually selected by one trained researcher ([31] using the Kubios software (v.”
MethodSelf-citationNavarro‐Lomas, G., Dote‐Montero, M., Alcántara, J. M. A., Plaza‐Florido, A., Castillo, M. J., & Amaro‐Gahete, F. J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04957-9 · Cited by 30
Self-citationPlaza‐Florido, A., Amaro‐Gahete, F. J., Acosta, F. M., Sacha, J., & Alcántara, J. M. A. (2021) · European Journal of Sport Science · doi:10.1080/17461391.2021.1892198 · Cited by 22
“…first 5 min were excluded and, from the remaining data, the “best” 5 min (i.e. those that followed a Gaussians R-R intervals distribution; did not present a large R-R interval outliers; and showed R-R intervals equidistance) were manually-selected for further analysis (Plaza-Florido et al., 2020).”
MethodSelf-citationMultifractal foundations of biomarker discovery for heart disease and stroke
Mangalam, M., Sadri, A., Hayano, J., Watanabe, E., Kiyono, K., & Kelty‐Stephen, D. G. (2023) · Scientific Reports · doi:10.1038/s41598-023-45184-2 · Cited by 25
Shin, D. Y., Hong, K. E., Lee, N. Y., Park, C. K., & Park, H. Y. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-09162-4 · Cited by 20
Canino, M. C., Dunn‐Lewis, C., Proessl, F., LaGoy, A. D., Hougland, J., Beck, A. L., Vaughan, G., Sterczala, A. J., Connaboy, C., Kraemer, W. J., et al. (2022) · Autonomic Neuroscience · doi:10.1016/j.autneu.2022.102953 · Cited by 15
Medrano, M., Molina‐Hidalgo, C., Alcántara, J. M. A., Ruiz, J. R., & Jurado‐Fasoli, L. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.858910 · Cited by 17
“, before the beverage intake), the best 5 min period of was manually selected by one trained evaluator (JMAA) based on the following criteria: (i) Gaussians R-R intervals and HR distribution graphs; (ii) no large R-R interval outliers; and (iii) R-R intervals equidistance (33).”
MethodEstimating Resting HRV during fMRI: A Comparison between Laboratory and Scanner Environment
Schumann, A., Suttkus, S., & Bär, K. (2021) · Sensors · doi:10.3390/s21227663 · Cited by 13
“Farah et al. (2016) reported ICCs ranging from 0.82 to 0.99, and Plaza-Florido et al. (2020) estimated ICC values between 0.70 and 0.99 [39,40].”
BackgroundInfluentialHow to properly evaluate cardiac vagal tone in oncology studies: a state-of-the-art review
Martinez, P., Grinand, M., Cheggour, S., Taieb, J., & Gourjon, G. (2024) · Journal of the National Cancer Center · doi:10.1016/j.jncc.2024.02.002 · Cited by 14
“119 Catai et al. 120 published guidelines and procedures for HRV analysis.”
Brandl, A., Engel, R., Egner, C., Schleip, R., & Schubert, C. (2024) · Journal of Medical Case Reports · doi:10.1186/s13256-024-04935-z · Cited by 10
Santos‐de‐Araújo, A. D., Dibai, D. B., Camargo, P. F., Marinho, R. S., Goulart, C. D. L., Dourado, I. M., Ricci, P. A., Mendes, R. G., & Borghi‐Silva, A. (2023) · Heart & Lung · doi:10.1016/j.hrtlng.2023.06.004 · Cited by 9
Navarro‐Lomas, G., Plaza‐Florido, A., De‐la‐O, A., Castillo, M. J., & Amaro‐Gahete, F. J. (2023) · American Journal of Human Biology · doi:10.1002/ajhb.23945 · Cited by 9
“We downloaded the R-R recordings using the Polar Pro Trainer 5 ® software (Polar Electro, Finland), and a trained researcher (Plaza-Florido et al., 2020) analyzed them with the Kubios HRV Standard ® , version 2.2 software (University of Eastern Finland, Kuopio, Finland) (Tarvainen et al., 2014).”
MethodInfluentialSelf-citationPoochipakorn, C., Wonghanchao, T., Huangsaksri, O., Sanigavatee, K., Joongpan, W., Tongsangiam, P., Charoenchanikran, P., & Chanda, M. (2023) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2023.104934 · Cited by 8
Acute physical exercise and ambulatory blood pressure in resistant hypertension
Saco‐Ledo, G., Valenzuela, P. L., Almazán-Polo, J., Plaza‐Florido, A., Alejo, L. B., Bustos, A., Río-García, A., Gálvez, B. G., Rubio-González, E., Fiuza‐Luces, C., et al. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003924 · Cited by 9
“Targeted proteomics We used proximity extension assay technology [43– the expression of 89 m we used Olink’s arbitrary unit (NPX values, normalized Protein expression values) in the log scale (i.e. a 1 NPX value difference means a doubling of protein concentration).”
Self-citationImpact of COVID-19 on heart rate variability in post-COVID individuals compared to a control group
Santos‐de‐Araújo, A. D., Dibai, D. B., Marinho, R. S., Dourado, I. M., de Almeida, L. V., dos Santos, S. D. S., Phillips, S. A., & Borghi‐Silva, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-82411-w · Cited by 11
Associations between Intra-Assessment Resting Metabolic Rate Variability and Health-Related Factors
Alcántara, J. M. A., Osuna‐Prieto, F. J., & Plaza‐Florido, A. (2022) · Metabolites · doi:10.3390/metabo12121218 · Cited by 7
“Finally, the R-R interval series were detrended using the smoothness prior method with alpha set at 500 ms and a cubic interpolation at the default rate of 4 Hz [36,38].”
MethodSelf-citationNavarro‐Lomas, G., Plaza‐Florido, A., De‐la‐O, A., Castillo, M. J., & Amaro‐Gahete, F. J. (2024) · Journal of Physiology and Biochemistry · doi:10.1007/s13105-023-01005-8 · Cited by 9
“A trained researcher [33] analyzed R-R recordings using the Kubios HRV Standard®, version 2.2 software (University of Eastern Finland, Kuopio, Finland) [42].”
InfluentialSelf-citationRuiz-Navarro, J. J., Plaza‐Florido, A., Alcántara, J. M. A., Gay, A., & Arellano, R. (2023) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2022-0389 · Cited by 5
Self-citationReducing decision-making deficits in patients with brain injury: effect of slow-paced breathing
Minjoz, S., Ottaviani, E., Phalempin, V., Barathon, G., Pellissier, S., & Hot, P. (2023) · Applied Neuropsychology Adult · doi:10.1080/23279095.2023.2166838 · Cited by 9
“The signal was carefully checked visually and remaining abnormalities were manually removed in accordance with published guidelines (Catai et al., 2020; Plaza-Florido et al., 2020; Quintana et al., 2016).”
de Almeida, L. V., Santos‐de‐Araújo, A. D., Cutrim, R. C., Tavarez, R. R. D. J., Borghi‐Silva, A., Pereira, F. H. F., Pontes‐Silva, A., Rêgo, A. S., Rocha, D. S., Marinho, R. S., et al. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192013587 · Cited by 5
“, a R–R interval much higher or lower than the whole R–R signal, based on the visual inspection of the HRV recording performed by the researcher), (2) R–R intervals equidistance and (3) Gaussian R–R intervals and heart rate distribution graphics [17].”
MethodHwang, B.-E., Kim, J., & Park, Y. (2024) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-024-06575-x · Cited by 3
“The utilization of short-term HRV enables the acquisition of precise and significant data in a controlled environment, thereby minimizing confounding factors compared to the use of long-term HRV assessments [21, 22].”
Santos‐de‐Araújo, A. D., Oliveira, M. R., Pontes‐Silva, A., Rodrigues, L. N., Costa, C. P. S., Marinho, R. S., dos Santos, S. D. S., Arena, R. A., Phillips, S. A., Dibai, D. B., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-77558-5 · Cited by 3
“…reliability of HRV, and good reliability rates have been found in diabetic individuals 36 , adolescents 42 , children 43 , young adults 43 , middle-aged adults 43 and post-COVID patients 19 , all using portable heart rate monitors for data collection and Kubios software for signal processing.”
BackgroundMethodInfluentialOne-week test–retest stability of heart rate variability during rest and deep breathing
Schumann, A., Lukas, F., Rieger, K., Gupta, Y., & Bär, K.-J. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adae51 · Cited by 7
“For instance, Farah et al (2014) reported ICC ranging from 0.82 to 0.99 and Plaza-Florido et al (2020) values between 0.70 and 0.99 as measures of inter-researcher reproducibility.”
InfluentialGonzález‐Acedo, A., Plaza‐Florido, A., Amaro‐Gahete, F. J., Sacha, J., & Alcántara, J. M. A. (2022) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2022.06.015 · Cited by 3
Self-citationAlcántara, J. M. A., González‐Acedo, A., Amaro‐Gahete, F. J., & Plaza‐Florido, A. (2024) · American Journal of Human Biology · doi:10.1002/ajhb.24157 · Cited by 2
Self-citationCutrim, R. C., Santos‐de‐Araújo, A. D., Anselmo-e-Silva, C. I., Brito-Monzani, J. D. O., Tavarez, R. R. D. J., Gonçalves, M. C., Filho, E. M. M., Borghi‐Silva, A., Dibai‐Filho, A. V., & Dibai, D. B. (2025) · Scientific Reports · doi:10.1038/s41598-025-00560-y · Cited by 2
“…were followed: (1) absence of large outliers in the R-R intervals (i.e., intervals much larger or smaller than the mean, as visually inspected by the researcher on the HRV recording); (2) equidistance of R-R intervals; and (3) Gaussian distribution of R-R intervals and heart rate curves 19,20 .”
Gąsior, J. S., Zamunér, A. R., Madeyska, M., Tomik, A., Niszczota, C. S., Williams, C. A., & Werner, B. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20020941 · Cited by 4
Al-Wahab, Z. N., Saleem, A. F., & Al‐Gailani, B. T. (2024) · Mustansiriya Medical Journal · doi:10.4103/mj.mj_7_24 · Cited by 2
Effects of Negative Emotions and Personality Traits on Laryngeal and Speech Motor Control
Çınar, B., Yılmaz, G., Konrot, A. K., Zraick, R. I., Saraç, A. B., Eteş, H., & Deger, Z. K. (2025) · Journal of Voice · doi:10.1016/j.jvoice.2025.05.032 · Cited by 2
A novel fatigue monitoring system using sweat lactate: a preliminary study
Takemoto, A., Okawara, H., Sudo, T., Sawada, T., Hirakawa, R., Muramoto, Y., Katsumata, Y., Nakamura, M., Nagura, T., & Nakashima, D. (2025) · Fatigue Biomedicine Health & Behavior · doi:10.1080/21641846.2025.2554557 · Cited by 3
“Recent progress has enabled the use of heart rate variability (HRV) for valid and reliable ANS monitoring [38, 39], including smartwatch applications [40]; therefore, ANS monitoring through HRV has become less invasive and more practical.”
Santos‐de‐Araújo, A. D., Dibai, D. B., Júnior, N. F. S., Garcia, B. R. D. O., Marinho, R. S., Ricci, P. A., Phillips, S. A., & Borghi‐Silva, A. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01499-x · Cited by 1
“R interval and heart rate graphs [11, 54].”
Plaza‐Florido, A., Olvera‐Rojas, M., Alcántara, J. M. A., Radom‐Aizik, S., & Ortega, F. B. (2024) · American Journal of Human Biology · doi:10.1002/ajhb.24113 · Cited by 1
“R intervals equidistance) and then selected to calculate HRV parameters using the Kubios software (Plaza-Florido et al., 2020).”
Self-citationNon-contact Heart Rate Measurement Based on Fusion Technology
Zou, J., Li, Y., & Bo, Z. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-78609-0_32
Brandl, A., Engel, R., Egner, C., Schleip, R., & Schubert, C. (2024) · Research Square · doi:10.21203/rs.3.rs-4544491/v1
SASSO, J. P., Coates, K. D., Stewart, L. C., Gelinas, J. C., Wright, S. P., Seiler, S., Shave, R., & Eves, N. D. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05641-w · Cited by 1
“Intraclass correlation coefficients were employed alongside 95% confidence intervals to assess the reliability and consistency of measurements obtained across various study timepoints (Plaza-Florido et al. 2020).”
Flanagan, S. D., Tompkins, R. D., Hougland, J., Hazelet, M. E., Moss, D., & Connaboy, C. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2025.12.12.693915
“5) [80-82].”
Turner, W., Marca, R. L., Infanger, D., Schwendinger, F., Brühl, A. B., Marschall, K., Schulze, B., Pfaff, M., Böker, H., Russmann, T., et al. (2026) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2026.112674
Han, X., Li, E. X., Volodarskiy, A., Slotwiner, D. J., & Zhao, Y. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae66c7
“…ECG recordings in three different cohorts: 107 children, 132 young adults, and 73 middle-aged adults, the ICCs of HRV parameters in the time-domain (RMSSD, pNN50, SDNN) ranged from 0.822 to 0.989, while for the frequency-domain (HF, LF, LF/HF) ranged from 0.703 to 0.985 (Plaza-Florido et al 2020).”
InfluentialTakai, K., Morikawa, N., & Yuda, E. (2026) · Electronics · doi:10.3390/electronics15163621
Navarro‐Lomas, G., De‐la‐O, A., Dote‐Montero, M., Castillo, M. J., Amaro‐Gahete, F. J., & Plaza‐Florido, A. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1920023
“To obtain reproducible and valid data, HRV analyses were performed by the same trained researcher (38).”
Self-citation
Metadata
- Authors
- Plaza-Florido, A., Alcantara, J. M. A., Migueles, J. H., Amaro-Gahete, F. J., Acosta, F. M., Mora-Gonzalez, J., Sacha, J., & Ortega, F. B.
- Affiliations
- Universidad de Granada (ES)
- Opole University of Technology (PL)
- Venue
- Scientific Reports
- Published
- 2020-07-09
- Volume
- 10
- Issue
- 1
- Pages
- 11399-11399
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC7347623
- OpenAlex
- W3041991105
- Cited by
- 44
- References
- 43
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 12 · 2023: 7 · 2022: 7 · 2021: 5 · 2020: 2
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Institutional Repository of the University of Granada (University of Granada) (publishedVersion, cc-by)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, cc-by)
- Funders
- The Spanish Ministry of Education, Culture and Sport ((FPU 16/02760), FPU15/04059, FPU15/02645, FPU14/04172, FPU14/06837)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Keywords
- heart rate variability, cardiac autonomic nervous system, young adults, middle-aged adults, limits of agreement, intraclass correlation coefficient
- MeSH terms
- Adult, Age Factors, Aging, Algorithms, Anthropometry, Child, Electrocardiography, Female, Heart Conduction System, Heart Rate, Humans, Male, Middle Aged, Obesity, Software, Reproducibility of Results, Cohort Studies, Observer Variation, Single-Blind Method, Overweight, Young Adult, Sedentary Behavior
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.