In vitro optoacoustic flow cytometry with light scattering referencing
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Morphological and functional optoacoustic imaging is enhanced by dedicated transgene reporters, in analogy to fluorescence methods. The development of optoacoustic reporters using protein engineering and directed evolution would be accelerated by high-throughput in-flow screening for intracellular, genetically encoded, optoacoustic contrast. However, accurate characterization of such contrast is impeded because the optoacoustic signals depend on the cell’s size and position in the flow chamber. We report herein an optoacoustic flow cytometer (OA-FCM) capable of precise measurement of intracellular optoacoustic signals of genetically-encoded chromoproteins in flow. The novel system records light-scattering as a reference for the detected optoacoustic signals in order to account for cell size and position, as well as excitation light flux in the focal volume, which we use to reference the detected optoacoustic signals to enhance the system’s precision. The OA-FCM was calibrated using micrometer-sized particles to showcase the ability to assess in-flow objects in the size range of single-cells. We demonstrate the capabilities of our OA-FCM to identify sub-populations in a mixture of two E. coli stocks expressing different reporter-proteins with a precision of over 90%. High-throughput screening of optoacoustic labels could pave the way for identifying genetically encoded optoacoustic reporters by transferring working concepts of the fluorescence field such as directed evolution and activated cell sorting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“However, due to the low light absorption of the individual microalgae cells, the simultaneous and in situ measurement of their label-free autofluorescence and laser-induced acoustic signals are still difficult and unreported [28].”
From Simultaneously Acquiring Optical and Acoustic Properties of Individual Microalgae Cells Suspended in Water (2022) · cites this paper as [28]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering and characterization of a superfolder green fluorescent protein
Pédelacq, J.-D., Cabantous, S., Tran, T., Terwilliger, T. C., & Waldo, G. S. (2006) · Nature Biotechnology · doi:10.1038/nbt1172 · Cited by 2,291
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Flow cytometry: basic principles and applications
Adan, A., Alizada, G., Kiraz, Y., Baran, Y., & Nalbant, A. (2017) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2015.1128876 · Cited by 920
Jeon, H., Lee, H., Kang, K. H., & Lim, G. (2014) · Scientific Reports · doi:10.1038/srep06668 · Cited by 844
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
Jathoul, A. P., Laufer, J., Ogunlade, O., Treeby, B., Cox, B., Zhang, E., Johnson, P., Pizzey, A. R., Philip, B., Marafioti, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.22 · Cited by 442
Label-free cell cycle analysis for high-throughput imaging flow cytometry
Blasi, T., Hennig, H., Summers, H. D., Theis, F. J., Cerveira, J., Patterson, J. O., Davies, D., Filby, A., Carpenter, A. E., & Rees, P. (2016) · Nature Communications · doi:10.1038/ncomms10256 · Cited by 299
Label-free metabolic imaging by mid-infrared optoacoustic microscopy in living cells
Pleitez, M. A., Khan, A. A., Soldà, A., Chmyrov, A., Reber, J., Gasparin, F., Seeger, M., Schätz, B., Herzig, S., Scheideler, M., et al. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0359-9 · Cited by 162
Self-citationLaufer, J. G., Jathoul, A. P., Pulè, M. A., & Beard, P. C. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.002477 · Cited by 81
Jo, Y., Jung, J., Lee, J. W., Shin, D., Park, H., Nam, K. T., Park, J., & Park, Y. (2014) · Scientific Reports · doi:10.1038/srep05090 · Cited by 69
Nedosekin, D. A., Sarimollaoglu, M., Galanzha, E. I., Sawant, R. R., Torchilin, V. P., Verkhusha, V. V., Ma, J., Frank, M. H., Biris, A. S., & Zharov, V. P. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200047 · Cited by 66
Optoacoustic microscopy at multiple discrete frequencies
Kellnberger, S., Soliman, D., Tserevelakis, G. J., Seeger, M., Yang, H., Karlas, A., Prade, L., Omar, M., & Ntziachristos, V. (2018) · Light Science & Applications · doi:10.1038/s41377-018-0101-2 · Cited by 62
Self-citationMultimodal optoacoustic and multiphoton microscopy of human carotid atheroma
Seeger, M., Karlas, A., Soliman, D., Pelisek, J., & Ntziachristos, V. (2016) · Photoacoustics · doi:10.1016/j.pacs.2016.07.001 · Cited by 53
Self-citationPushing the boundaries of optoacoustic microscopy by total impulse response characterization
Seeger, M., Soliman, D., Aguirre, J., Diot, G., Wierzbowski, J., & Ntziachristos, V. (2020) · Nature Communications · doi:10.1038/s41467-020-16565-2 · Cited by 49
Self-citationHigh‐precision characterization of individual E. coli cell morphology by scanning flow cytometry
Konokhova, A. I., Gelash, A. A., Yurkin, M. A., Chernyshev, A. V., & Maltsev, V. P. (2013) · Cytometry Part A · doi:10.1002/cyto.a.22294 · Cited by 45
Simultaneous acoustic and photoacoustic microfluidic flow cytometry for label-free analysis
Gnyawali, V., Strohm, E. M., Wang, J., Tsai, S. S. H., & Kolios, M. C. (2019) · Scientific Reports · doi:10.1038/s41598-018-37771-5 · Cited by 43
Engineering Dark Chromoprotein Reporters for Photoacoustic Microscopy and FRET Imaging
Li, Y., Forbrich, A., Wu, J., Shao, P., Campbell, R. E., & Zemp, R. J. (2016) · Scientific Reports · doi:10.1038/srep22129 · Cited by 41
High-Speed Multiparameter Photophysical Analyses of Fluorophore Libraries
Dean, K. M., Davis, L. M., Lubbeck, J. L., Manna, P., Friis, P., Palmer, A. E., & Jimenez, R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00607 · Cited by 35
IndividualEscherichia coli cells studied from light scattering with the scanning flow cytometer
Shvalov, А. N., Soini, J. T., Surovtsev, I. V., Kochneva, G. V., Sivolobova, G. F., Petrov, A. K., & Maltsev, V. P. (2000) · Cytometry · doi:10.1002/1097-0320(20000901)41:1<41::aid-cyto6>3.0.co;2-n · Cited by 32
Light scattering and absorption caused by bacterial activity in water
Waltham, C., Boyle, J., Ramey, B., & Smit, J. (1994) · Applied Optics · doi:10.1364/ao.33.007536 · Cited by 31
Photoacoustic flow cytometry for nanomaterial research
Nedosekin, D. A., Fahmi, T., Nima, Z. A., Nolan, J., Cai, C., Sarimollaoglu, M., Dervishi, E., Basnakian, A. G., Biris, A. S., & Zharov, V. P. (2017) · Photoacoustics · doi:10.1016/j.pacs.2017.03.002 · Cited by 26
Defacque, H., Egeberg, M., Antzberger, A., Ansorge, W., Way, M., & Griffiths, G. (2000) · Cytometry · doi:10.1002/1097-0320(20000901)41:1<1::aid-cyto1>3.3.co;2-v · Cited by 22
Photocontrollable Proteins for Optoacoustic Imaging
Mishra, K., Fuenzalida-Werner, J. P., Ntziachristos, V., & Stiel, A. C. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01048 · Cited by 21
Self-citationHigh-Throughput Platform for Optoacoustic Probing of Genetically Encoded Calcium Ion Indicators
Hofmann, U., Fabritius, A., Rebling, J., Estrada, H., Deán‐Ben, X. L., Griesbeck, O., & Razansky, D. (2019) · iScience · doi:10.1016/j.isci.2019.11.034 · Cited by 6
Nedosekin, D. A., Sarimollaoglu, M., Foster, S., Galanzha, E. I., & Zharov, V. P. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2006304 · Cited by 4
In-vivo hybrid microscopy of small model organisms
Seeger, M., Westmeyer, G. G., & Ntziachristos, V. (2019) · Opto-Acoustic Methods and Applications in Biophotonics · doi:10.1117/12.2530923 · Cited by 4
Self-citationOptoacoustic flow-cytometry with light scattering referencingPreprint
Seeger, M., Stiel, A. C., & Ntziachristos, V. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.02.04.933705 · Cited by 1
Self-citation
Cited by
Fate of antibiotic resistant genes in wastewater environments and treatment strategies - A review
Manoharan, R. K., Ishaque, F., & Ahn, Y. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.134671 · Cited by 116
Wang, X., Howe, S. M., Deng, F., & Zhao, J. (2021) · Microorganisms · doi:10.3390/microorganisms9091797 · Cited by 88
Zhao, W., Yu, H., Wen, Y., Luo, H., Jia, B., Wang, X., Liu, L., & Li, W. J. (2021) · Lab on a Chip · doi:10.1039/d1lc00263e · Cited by 17
Seeger, M., Dehner, C., Jüstel, D., & Ntziachristos, V. (2021) · Communications Biology · doi:10.1038/s42003-021-02573-5 · Cited by 16
Self-citationWang, H., Liao, R., Xiong, Z., Wang, Z., Li, J., Zhou, Q., Tao, Y., & Ma, H. (2022) · Biosensors · doi:10.3390/bios12030176 · Cited by 10
Metadata
- Authors
- Seeger, M., Stiel, A. C., & Ntziachristos, V.
- Affiliations
- Helmholtz Munich (DE)
- Corresponding author
- Ntziachristos, Vasilis
- Venue
- Scientific Reports
- Published
- 2021-01-26
- Volume
- 11
- Issue
- 1
- Pages
- 2181-2181
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC7838204
- OpenAlex
- W3124549009
- Cited by
- 8
- References
- 25
- Citations by year
- 2025: 2 · 2023: 1 · 2022: 3 · 2021: 2
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion, cc-by)
- Site cant be reached (submittedVersion, cc-by)
- Funders
- Deutsche Forschungsgemeinschaft (NT 3/10-1, STI656/1-1)
- Projekt DEAL
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- photoacoustic imaging, chromoproteins, high-throughput screening, Escherichia coli, subpopulation identification, directed evolution
- MeSH terms
- Escherichia coli, Flow Cytometry, Scattering, Radiation, Signal Processing, Computer-Assisted, Reproducibility of Results, Photoacoustic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.