A preliminary deep learning study on automatic segmentation of contrast-enhanced bolus in videofluorography of swallowing
Open accessThe DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
Although videofluorography (VFG) is an effective tool for evaluating swallowing functions, its accurate evaluation requires considerable time and effort. This study aimed to create a deep learning model for automated bolus segmentation on VFG images of patients with healthy swallowing and dysphagia using the artificial intelligence deep learning segmentation method, and to assess the performance of the method. VFG images of 72 swallowing of 12 patients were continuously converted into 15 static images per second. In total, 3910 images were arbitrarily assigned to the training, validation, test 1, and test 2 datasets. In the training and validation datasets, images of colored bolus areas were prepared, along with original images. Using a U-Net neural network, a trained model was created after 500 epochs of training. The test datasets were applied to the trained model, and the performances of automatic segmentation (Jaccard index, Sørensen–Dice coefficient, and sensitivity) were calculated. All performance values for the segmentation of the test 1 and 2 datasets were high, exceeding 0.9. Using an artificial intelligence deep learning segmentation method, we automatically segmented the bolus areas on VFG images; our method exhibited high performance. This model also allowed assessment of aspiration and laryngeal invasion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“deep learning models like U-Net and CNNs have achieved performance metrics such as F1 scores exceeding 0.9 and accuracy rates of 97.8%, indicating their robustness in detecting swallowing events and anatomical structures.”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [68]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Other methods, including support vector machines (SVM) and Mask-RCNN, have demonstrated high accuracy in classifying swallowing events, with metrics like sensitivity and specificity reaching over 90%.”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [68]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“These findings emphasize the potential of AI-driven tools in improving diagnostic accuracy for dysphagia(51,68,69,75).”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [68]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 12 · Cited by 19
Metadata
- Authors
- Ariji, Y., Gotoh, M., Fukuda, M., Watanabe, S., Nagao, T., Katsumata, A., & Ariji, E.
- Affiliations
- Aichi Gakuin University (JP)
- Asahi University (JP)
- Corresponding author
- Ariji, Eiichiro
- Venue
- Scientific Reports
- Published
- 2022-11-05
- Volume
- 12
- Issue
- 1
- Pages
- 18754-18754
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC9637105
- OpenAlex
- W4308262271
- Cited by
- 19
- References
- 12
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 4 · 2023: 5
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Japan Society for the Promotion of Science (20K10194)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
- Keywords
- videofluorography, swallowing, dysphagia, U-Net, deep learning segmentation, aspiration, laryngeal invasion
- MeSH terms
- Deep Learning, Artificial Intelligence, Deglutition, Humans, Image Processing, Computer-Assisted, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A preliminary deep learning study on automatic segmentation of contrast-enhanced bolus in videofluorography of swallowing. https://app.cochat.ai/papers/10.1038/s41598-022-21530-8
- The paper
- Ariji, Y., Gotoh, M., Fukuda, M., Watanabe, S., Nagao, T., Katsumata, A., & Ariji, E. (2022). A preliminary deep learning study on automatic segmentation of contrast-enhanced bolus in videofluorography of swallowing. Scientific Reports. https://doi.org/10.1038/s41598-022-21530-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.