Photovoltaic organic interface for neuronal stimulation in the near-infrared
Open accessAbstract
Abstract Organic materials, such as conjugated polymers, are attractive building blocks for bioelectronic interfaces. In particular, organic semiconductors show excellent performance in light-mediated excitation and silencing of neuronal cells and tissues. However, the main challenges of these organic photovoltaic interfaces compared to inorganic prostheses are the limited adhesion of conjugated polymers in aqueous environments and the exploitation of materials responsive in the visible spectrum. Here, we show a photovoltaic organic interface optimized for neuronal stimulation in the near-infrared spectrum. We adjusted the organic materials by chemical modification in order to improve the adhesion in an aqueous environment and to modulate the photoelectrical stimulation efficiency. As proof-of-principle, we tested this interface on explanted degenerated mice retinas, thus providing results on the efficiency and reliability of the device as an implant for neural stimulation.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
POLYRETINA is a high-density wide-field epiretinal prosthesis containing 10,498 photovoltaic pixels distributed over an active area of approximately 43°.
“POLYRETINA is a high-density wide-field epiretinal prosthesis containing 10 498 photovoltaic pixels distributed over an active area of approximately 43 • [38,39,131,132].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [131]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 62 · Cited by 63
- Authors
- Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- University of Basel (CH)
- Corresponding author
- Ghezzi, Diego
- Venue
- Communications Materials
- Published
- 2020-05-01
- Volume
- 1
- Issue
- 1
- ISSN
- 2662-4443 (ISSN-L)
- OpenAlex
- W3021023113
- Cited by
- 63
- References
- 62
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 10 · 2023: 14 · 2022: 8 · 2021: 15 · 2020: 3
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Communications Materials (publishedVersion, cc-by)
- DORA Empa (Swiss Federal Laboratories for Materials Science and Technology (Empa)) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- Gebert Rüf Stiftung (GRS-035/17)
- Velux Stiftung (1102)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- neurostimulation, near-infrared light, conjugated polymers, organic semiconductors, bioelectronic interfaces, chemical modification, retinal prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review