Detection of circulating tumour cells in peripheral blood with an automated scanning fluorescence microscope
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We have developed an automated, highly sensitive and specific method for identifying and enumerating circulating tumour cells (CTCs) in the blood. Blood samples from 10 prostate, 25 colorectal and 4 ovarian cancer patients were analysed. Eleven healthy donors and seven men with elevated serum prostate-specific antigen (PSA) levels but no evidence of malignancy served as controls. Spiking experiments with cancer cell lines were performed to estimate recovery yield. Isolation was performed either by density gradient centrifugation or by filtration, and the CTCs were labelled with monoclonal antibodies against cytokeratins 7/8 and either AUA1 (against EpCam) or anti-PSA. The slides were analysed with the Ikoniscope robotic fluorescence microscope imaging system. Spiking experiments showed that less than one epithelial cell per millilitre of blood could be detected, and that fluorescence in situ hybridisation (FISH) could identify chromosomal abnormalities in these cells. No positive cells were detected in the 11 healthy control samples. Circulating tumour cells were detected in 23 out of 25 colorectal, 10 out of 10 prostate and 4 out of 4 ovarian cancer patients. Five samples (three colorectal and two ovarian) were analysed by FISH for chromosomes 7 and 8 combined and all had significantly more than four dots per cell. We have demonstrated an Ikoniscope based relatively simple and rapid procedure for the clear-cut identification of CTCs. The method has considerable promise for screening, early detection of recurrence and evaluation of treatment response for a wide variety of carcinomas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of P53 mutations and their expression in 56 colorectal cancer cell lines
Liu, Y., & Bodmer, W. F. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0510146103 · Cited by 257
Self-citation
Cited by
Circulating Tumor Cells: Liquid Biopsy of Cancer
Alix-Panabières, C., & Pantel, K. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.194258 · Cited by 1,134
Circulating tumour cells in cancer patients: challenges and perspectives
Pantel, K., & Alix-Panabières, C. (2010) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2010.07.001 · Cited by 815
Pantel, K., Alix-Panabières, C., & Riethdorf, S. (2009) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.44 · Cited by 643
Circulating Tumor Cells and Circulating Tumor DNA
Alix-Panabières, C., Schwarzenbach, H., & Pantel, K. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-062310-094219 · Cited by 485
Isolation of rare cells from cell mixtures by dielectrophoresis
Gascoyne, P. R. C., Noshari, J., Anderson, T. J., & Becker, F. F. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800373 · Cited by 436
Metadata
- Authors
- Ntouroupi, T. G., Ashraf, S. Q., McGregor, S. B., Turney, B. W., Seppo, A., Kim, Y., Wang, X., Kilpatrick, M. W., Tsipouras, P., Tafas, T., & Bodmer, W. F.
- Venue
- British Journal of Cancer
- Published
- 2008-08-05
- Volume
- 99
- Issue
- 5
- Pages
- 789-795
- ISSN
- 0007-0920 (ISSN-L)
- 1532-1827
- OpenAlex
- W4233588645
- Cited by
- 116
- References
- 1
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.