CoChat

Positron Emission Tomography Displacement Sensitivity: Predicting Binding Potential Change for Positron Emission Tomography Tracers Based on Their Kinetic Characteristics

Morris, Evan D, Yoder, Karmen K · 2007 · Journal of Cerebral Blood Flow & Metabolism
Cited by 54

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

There is great interest in positron emission tomography (PET) as a noninvasive assay of fluctuations in synaptic neurotransmitter levels, but questions remain regarding the optimal choice of tracer for such a task. A mathematical method is proposed for predicting the utility of any PET tracer as a detector of changes in the concentration of an endogenous competitor via displacement of the tracer (a.k.a., its ‘vulnerability’ to competition). The method is based on earlier theoretical work by Endres and Carson and by the authors. A tracer-specific predictor, the PET Displacement Sensitivity (PDS), is calculated from compartmental model simulations of the uptake and retention of dopaminergic radiotracers in the presence of transient elevations of dopamine (DA). The PDS predicts the change in binding potential (Δ BP) for a given change in receptor occupancy because of binding by the endogenous competitor. Simulations were performed using estimates of tracer kinetic parameters derived from the literature. For D 2/D 3 tracers, the calculated PDS indices suggest a rank order for sensitivity to displacement by DA as follows: raclopride (highest sensitivity), followed by fallypride, FESP, FLB, NMSP, and epidepride (lowest). Although the PDS takes into account the affinity constant for the tracer at the binding site, its predictive value cannot be matched by either a single equilibrium constant, or by any one rate constant of the model. Values for Δ BP have been derived from published studies that employed comparable displacement paradigms with amphetamine and a D 2/D 3 tracer. The values are in good agreement with the PDS-predicted rank order of sensitivity to displacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/sj.jcbfm.9600359

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 54

Metadata

Authors
Morris, E. D., & Yoder, K. K.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
2007-03
Volume
27
Issue
3
Pages
606-617
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2161308029
Cited by
54
References
4
FWCI
2.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Positron Emission Tomography Displacement Sensitivity: Predicting Binding Potential Change for Positron Emission Tomography Tracers Based on Their Kinetic Characteristics. https://app.cochat.ai/papers/10.1038/sj.jcbfm.9600359
The paper
Morris, E. D., & Yoder, K. K. (2007). Positron Emission Tomography Displacement Sensitivity: Predicting Binding Potential Change for Positron Emission Tomography Tracers Based on Their Kinetic Characteristics. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/sj.jcbfm.9600359

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.