CoChat

Antiproton induced DNA damage: proton like in flight, carbon-ion like near rest

Open access

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

Biological validation of new radiotherapy modalities is essential to understand their therapeutic potential. Antiprotons have been proposed for cancer therapy due to enhanced dose deposition provided by antiproton-nucleon annihilation. We assessed cellular DNA damage and relative biological effectiveness (RBE) of a clinically relevant antiproton beam. Despite a modest LET (~19 keV/μm), antiproton spread out Bragg peak (SOBP) irradiation caused significant residual γ-H2AX foci compared to X-ray, proton and antiproton plateau irradiation. RBE of ~1.48 in the SOBP and ~1 in the plateau were measured and used for a qualitative effective dose curve comparison with proton and carbon-ions. Foci in the antiproton SOBP were larger and more structured compared to X-rays, protons and carbon-ions. This is likely due to overlapping particle tracks near the annihilation vertex, creating spatially correlated DNA lesions. No biological effects were observed at 28-42 mm away from the primary beam suggesting minimal risk from long-range secondary particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep01770

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Initial and residual γ-H2AX foci were observed in charged particle irradiated fibroblasts. (a) γ-H2AX foci (green) were imaged at 1 and 26 h after irradiation with antiprotons (top), carbon ions, protons or 225 kVp X-rays. (b) ‘Cut-view' images taken from compiled Z-stack images through irradiated cells show stacks of foci along antiproton paths in SOBP irradiated cells that were fixed 1 h after irradiation. (c) Restoration deconvolution was applied to images of cell nuclei from antiproton-irradiated fibroblasts. Antiproton SOBP irradiated nuclei (top) contained large clustered foci that were smaller and less frequent in antiproton plateau irradiated fibroblasts (bottom).
Figure 1 Initial and residual γ-H2AX foci were observed in charged particle irradiated fibroblasts. (a) γ-H2AX foci (green) were imaged at 1 and 26 h after irradiation with antiprotons (top), carbon ions, protons or 225 kVp X-rays. (b) ‘Cut-view' images taken from compiled Z-stack images through irradiated cells show stacks of foci along antiproton paths in SOBP irradiated cells that were fixed 1 h after irradiation. (c) Restoration deconvolution was applied to images of cell nuclei from antiproton-irradiated fibroblasts. Antiproton SOBP irradiated nuclei (top) contained large clustered foci that were smaller and less frequent in antiproton plateau irradiated fibroblasts (bottom).CC BY-NC-ND · PubMed Central
Figure 2 Kinetics of antiproton induced γ-H2AX foci. (a) The mean number of foci/cell/Gy was quantified in cells exposed to X-rays, 126 MeV antiprotons (in plateau or mid-SOBP), 62 MeV protons (proximal to or in the middle of the SOBP) and 62 MeV/u carbon ions (70 or 150 keV/μm. The data are presented as the mean of three independent experiments, normalized to sham irradiated controls. Error bars represent the standard error. (b) The full-width at half maximum (FWHM, μm) were calculated for foci in 30 nuclei of each group. (c) The foci resolution kinetics was plotted as a measure of DNA damage repair. Foci were scored in >100 nuclei per slide. The data presented are the mean and standard error.
Figure 2 Kinetics of antiproton induced γ-H2AX foci. (a) The mean number of foci/cell/Gy was quantified in cells exposed to X-rays, 126 MeV antiprotons (in plateau or mid-SOBP), 62 MeV protons (proximal to or in the middle of the SOBP) and 62 MeV/u carbon ions (70 or 150 keV/μm. The data are presented as the mean of three independent experiments, normalized to sham irradiated controls. Error bars represent the standard error. (b) The full-width at half maximum (FWHM, μm) were calculated for foci in 30 nuclei of each group. (c) The foci resolution kinetics was plotted as a measure of DNA damage repair. Foci were scored in >100 nuclei per slide. The data presented are the mean and standard error.CC BY-NC-ND · PubMed Central
Figure 3 Cell survival and RBE estimations. Survival of AG01522 cells as a function of dose when the cells were irradiated with (a) 126 MeV antiprotons, (b) 62 MeV protons and (c) 62 MeV/u carbon ions. Error bars indicate the standard error of measurements from at least two independent experiments. X-ray, proton and carbon ion measurements were all performed three times. Antiproton measurements were performed three times for all doses except the highest two, which were performed twice. Survival data are fit to a weighted linear quadratic model.
Figure 3 Cell survival and RBE estimations. Survival of AG01522 cells as a function of dose when the cells were irradiated with (a) 126 MeV antiprotons, (b) 62 MeV protons and (c) 62 MeV/u carbon ions. Error bars indicate the standard error of measurements from at least two independent experiments. X-ray, proton and carbon ion measurements were all performed three times. Antiproton measurements were performed three times for all doses except the highest two, which were performed twice. Survival data are fit to a weighted linear quadratic model.CC BY-NC-ND · PubMed Central
Figure 4 Long-range annihilation particles have RBE similar to X-rays. (a) Antiproton-nucleon annihilation produces a number of long range particles such gamma rays, neutrons and positive, negative and neutral pions. (b) γ-H2AX foci were scored in cells positioned directly in the beam at the mid-point of the SOBP (solid black circle) and in an adjacent flask at either 28 or 42 mm from the centre of the beam (0 mm). A significant increase in DNA damage was only observed at 1 h after exposure when the in-beam target received 5.56 Gy. P = 0.026 when compared to mock irradiated control by student's T test. Foci were scored in 200 nuclei per sample. (c) Cells were positioned adjacent to in beam samples (approximately 35 mm from the centre of the beam) and were reseeded at clonal density post irradiation in parallel with directly irradiated cells. The dose at 35 mm from the beam centre is estimated to be <10% of the dose at the centre of the beam.
Figure 4 Long-range annihilation particles have RBE similar to X-rays. (a) Antiproton-nucleon annihilation produces a number of long range particles such gamma rays, neutrons and positive, negative and neutral pions. (b) γ-H2AX foci were scored in cells positioned directly in the beam at the mid-point of the SOBP (solid black circle) and in an adjacent flask at either 28 or 42 mm from the centre of the beam (0 mm). A significant increase in DNA damage was only observed at 1 h after exposure when the in-beam target received 5.56 Gy. P = 0.026 when compared to mock irradiated control by student's T test. Foci were scored in 200 nuclei per sample. (c) Cells were positioned adjacent to in beam samples (approximately 35 mm from the centre of the beam) and were reseeded at clonal density post irradiation in parallel with directly irradiated cells. The dose at 35 mm from the beam centre is estimated to be <10% of the dose at the centre of the beam.CC BY-NC-ND · PubMed Central
Figure 5 Simulated dose profiles. Depth and lateral dose profiles for simulated clinically relevant (10 mm SOBP) proton (blue line; 120 MeV), carbon (green line; 240 MeV/u) and antiproton beams (red line; 120 MeV). Effective dose profiles obtained from the physical dose profiles and considering the RBESOBP/plateau ratios reported in this work.
Figure 5 Simulated dose profiles. Depth and lateral dose profiles for simulated clinically relevant (10 mm SOBP) proton (blue line; 120 MeV), carbon (green line; 240 MeV/u) and antiproton beams (red line; 120 MeV). Effective dose profiles obtained from the physical dose profiles and considering the RBESOBP/plateau ratios reported in this work.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Abramoff, M. D., Magelhaes, P. J. & Ram, S. J. Image processing with Image J. Biophotonics International 11, 36–42 (2004).

Cited by

See all 26

Metadata

Authors
Kavanagh, J. N., Currell, F. J., Timson, D. J., Savage, K. I., Richard, D. J., McMahon, S. J., Hartley, O., Cirrone, G. A. P., Romano, F., Prise, K. M., Bassler, N., Holzscheiter, M. H., & Schettino, G.
Affiliations
  • Queen's University Belfast (GB)
  • Queensland University of Technology (AU)
  • University of Geneva (CH)
  • Istituto Nazionale di Fisica Nucleare, Sezione di Catania (IT)
  • Aarhus University (DK)
  • University of New Mexico (US)
Corresponding author
Kavanagh, J. N.
Venue
Scientific Reports
Published
2013-05-03
Volume
3
Issue
1
Pages
1770-1770
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2112352029
Cited by
26
References
43
Citations by year
2023: 2 · 2022: 3 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 4 · 2016: 2 · 2015: 5 · 2014: 3
FWCI
2.72
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Archive ouverte UNIGE (University of Geneva) (publishedVersion, other-oa)
  • Research Portal (Queen's University Belfast) (acceptedVersion, cc-by-nc-nd)
  • QUT ePrints (Queensland University of Technology) (submittedVersion)
  • Research Explorer (The University of Manchester) (submittedVersion)
  • University of Brighton Repository (University of Brighton) (submittedVersion)
  • GSI Repository (German Federal Government) (submittedVersion, other-oa)
  • Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
  • GSI Repository (German Federal Government)
Funders
  • European Commission (262010, 2007–2013, FP7 2007-2013, FP7/2007)
  • Engineering and Physical Sciences Research Council (EP/H017844/1, EP/I017550/1)
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
Keywords
antiprotons, DNA damage, relative biological effectiveness, spread-out Bragg peak, antiproton-nucleon annihilation, γH2AX foci, carbon ion radiotherapy, proton therapy, LET, secondary particles, effective dose
MeSH terms
Carbon, Cell Survival, Cells, Cultured, DNA Damage, Humans, Ions, Protons, Radiotherapy, Radiotherapy Dosage, Relative Biological Effectiveness, X-Rays

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.