Nanocomposite based flexible ultrasensitive resistive gas sensor for chemical reactions studies
Open accessThe DOI matches its Crossref record.
Abstract
Room temperature operation, low detection limit and fast response time are highly desirable for a wide range of gas sensing applications. However, the available gas sensors suffer mainly from high temperature operation or external stimulation for response/recovery. Here, we report an ultrasensitive-flexible-silver-nanoparticle based nanocomposite resistive sensor for ammonia detection and established the sensing mechanism. We show that the nanocomposite can detect ammonia as low as 500 parts-per-trillion at room temperature in a minute time. Furthermore, the evolution of ammonia from different chemical reactions has been demonstrated using the nanocomposite sensor as an example. Our results demonstrate the proof-of-concept for the new detector to be used in several applications including homeland security, environmental pollution and leak detection in research laboratories and many others.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shi, Q., Dong, B., He, T., Sun, Z., Zhu, J., Zhang, Z., & Lee, C. (2020) · InfoMat · doi:10.1002/inf2.12122 · Cited by 661
Organic–Inorganic Hybrid Nanocomposite-Based Gas Sensors for Environmental Monitoring
Kaushik, A., Kumar, R., Arya, S. K., Nair, M., Malhotra, B. D., & Bhansali, S. (2015) · Chemical Reviews · doi:10.1021/cr400659h · Cited by 534
Thakur, S., Pandey, S., & Arotiba, O. A. (2016) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2016.06.104 · Cited by 407
Self-citationPandey, S. (2017) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2017.06.115 · Cited by 338
Self-citationPandey, S. (2016) · Journal of Science: Advanced Materials and Devices · doi:10.1016/j.jsamd.2016.10.005 · Cited by 310
Self-citation
Metadata
- Authors
- Pandey, S., Goswami, G. K., & Nanda, K. K.
- Venue
- Scientific Reports
- Published
- 2013-06-27
- Volume
- 3
- Issue
- 1
- Pages
- 2082-2082
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2031572787
- Cited by
- 129
- References
- 0
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanocomposite based flexible ultrasensitive resistive gas sensor for chemical reactions studies. https://app.cochat.ai/papers/10.1038/srep02082
- The paper
- Pandey, S., Goswami, G. K., & Nanda, K. K. (2013). Nanocomposite based flexible ultrasensitive resistive gas sensor for chemical reactions studies. Scientific Reports. https://doi.org/10.1038/srep02082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.