Highly Efficient Electronic Sensitization of Non-oxidized Graphene Flakes on Controlled Pore-loaded WO3 Nanofibers for Selective Detection of H2S Molecules
Open accessThe DOI matches its Crossref record.
Abstract
Tailoring of semiconducting metal oxide nanostructures, which possess controlled pore size and concentration, is of great value to accurately detect various volatile organic compounds in exhaled breath, which act as potential biomarkers for many health conditions. In this work, we have developed a very simple and robust route for controlling both the size and distribution of spherical pores in electrospun WO3 nanofibers (NFs) via a sacrificial templating route using polystyrene colloids with different diameters (200 nm and 500 nm). A tentacle-like structure with randomly distributed pores on the surface of electrospun WO3 NFs were achieved, which exhibited improved surface area as well as porosity. Porous WO3 NFs with enhanced surface area exhibited high gas response (Rair/Rgas = 43.1 at 5 ppm) towards small and light H2S molecules. In contrast, porous WO3 NFs with maximized pore diameter showed a high response (Rair/Rgas = 2.8 at 5 ppm) towards large and heavy acetone molecules. Further enhanced sensing performance (Rair/Rgas = 65.6 at 5 ppm H2S) was achieved by functionalizing porous WO3 NFs with 0.1 wt% non-oxidized graphene (NOGR) flakes by forming a Schottky barrier (ΔΦ = 0.11) at the junction between the WO3 NFs (Φ = 4.56 eV) and NOGR flakes (Φ = 4.67 eV), which showed high potential for the diagnosis of halitosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Graphene-based smart materials
Yu, X., Cheng, H., Zhang, M., Zhao, Y., Qu, L., & Shi, G. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.46 · Cited by 796
Flexible Graphene-Based Wearable Gas and Chemical Sensors
Singh, E., Meyyappan, M., & Nalwa, H. S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07063 · Cited by 776
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
A Review on Graphene-Based Gas/Vapor Sensors with Unique Properties and Potential Applications
Wang, T., Huang, D., Yang, Z., Xu, S., He, G., Li, X., Hu, N., Yin, G., He, D., & Zhang, L. (2016) · Nano-Micro Letters · doi:10.1007/s40820-015-0073-1 · Cited by 600
Koo, W.-T., Choi, S.-J., Kim, S.-J., Jang, J.-S., Tuller, H. L., & Kim, I.-D. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b09167 · Cited by 424
Self-citation
Metadata
- Authors
- Choi, S., Choi, C., Kim, S.-J., Cho, H.-J., Hakim, M., Jeon, S., & Kim, I.
- Venue
- Scientific Reports
- Published
- 2015-01-28
- Volume
- 5
- Issue
- 1
- Pages
- 8067-8067
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2062934043
- Cited by
- 85
- References
- 0
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Efficient Electronic Sensitization of Non-oxidized Graphene Flakes on Controlled Pore-loaded WO3 Nanofibers for Selective Detection of H2S Molecules. https://app.cochat.ai/papers/10.1038/srep08067
- The paper
- Choi, S., Choi, C., Kim, S.-J., Cho, H.-J., Hakim, M., Jeon, S., & Kim, I. (2015). Highly Efficient Electronic Sensitization of Non-oxidized Graphene Flakes on Controlled Pore-loaded WO3 Nanofibers for Selective Detection of H2S Molecules. Scientific Reports. https://doi.org/10.1038/srep08067
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.