Abstract

Plasma glucose levels provide the cornerstone of diabetes evaluation. Unfortunately, glucose levels drop in vitro due to glycolysis. Guidelines provide suitable conditions which minimize glycolysis, such as immediate centrifugation or the use of ice/water slurry storage containers. For obvious practical reasons, most laboratories use blood collection tubes containing glycolysis inhibitors. We describe the effect of a variety of commonly used blood collection tubes on in vitro stability of glucose. Furthermore, we looked at the validity of the assumption that glycolytic activity is minimal when blood is kept in an ice/water slurry. Sodium fluoride alone does not reduce in vitro glycolysis in the first 120 minutes after phlebotomy. Addition of citrate almost completely prevented in vitro glycolysis, but showed a positive bias (0.2 mmol/l) compared to control. This is partly due to a small drop in glucose level in control blood, drawn according to the current guidelines. This drop occurs within 15 minutes, in which glycolysis has been described to be minimal and acceptable. NaF-EDTA-citrate based test tubes provide the best pre-analytical condition available. Furthermore, glucose levels are not stable in heparinized blood placed in an ice/water slurry. We strongly advise the use of NaF-EDTA-citrate based test tubes in diabetes research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep08875

Cites

Statistics

Figures

Figure 1 Time and tube type dependent changes of glucose concentration. (A): Glucose concentration difference compared to control (lithium-heparin, kept on ice, measured at t = 0). Bars represent the different time points, from left to right: 0, 30, 60, 120 minutes. (B): Time dependent changes in glucose concentrations compared to the concentration measured in the same tube type at t = 0. Bars represent the different time points, from left to right: 30, 60 and 120 minutes. Bars represent mean plus SD, **p < 0.01 for tube type/time interaction by two-way ANOVA, when compared to lithium-heparin tubes.
Figure 1 Time and tube type dependent changes of glucose concentration. (A): Glucose concentration difference compared to control (lithium-heparin, kept on ice, measured at t = 0). Bars represent the different time points, from left to right: 0, 30, 60, 120 minutes. (B): Time dependent changes in glucose concentrations compared to the concentration measured in the same tube type at t = 0. Bars represent the different time points, from left to right: 30, 60 and 120 minutes. Bars represent mean plus SD, **p < 0.01 for tube type/time interaction by two-way ANOVA, when compared to lithium-heparin tubes.CC BY · PubMed Central
Figure 2 Time and temperature dependent changes of glucose concentration. (A): Time dependent change in core temperature and (B): changes in glucose concentration in heparinized blood placed in an ice/water slurry. Lines represent mean plus SD.
Figure 2 Time and temperature dependent changes of glucose concentration. (A): Time dependent change in core temperature and (B): changes in glucose concentration in heparinized blood placed in an ice/water slurry. Lines represent mean plus SD.CC BY · PubMed Central
Figure 3 Time and tube type dependent free hemoglobin concentration and icteric index. Free hemoglobin concentration and icteric index at 0, 30, 60 and 120 minute time points, depicted per tube type, time points from left to right. Bars represent the different time points, from left to right: 0, 30, 60, 120 minutes. Bars represent mean plus SD, *p < 0.05 and **p < 0.01 for tube type/time interaction by two-way ANOVA, when compared to lithium-heparin tubes.
Figure 3 Time and tube type dependent free hemoglobin concentration and icteric index. Free hemoglobin concentration and icteric index at 0, 30, 60 and 120 minute time points, depicted per tube type, time points from left to right. Bars represent the different time points, from left to right: 0, 30, 60, 120 minutes. Bars represent mean plus SD, *p < 0.05 and **p < 0.01 for tube type/time interaction by two-way ANOVA, when compared to lithium-heparin tubes.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 16 · Cited by 49

Research works printed but not linked: 1

  1. van den Berg, S. A. A., Thelen, M. H. M. & Boonen, K. J. Inventarisatie van de (pre)analytische aspecten van de glucose bepaling in nederlandse laboratoria; tijd voor uniformiteit. Ned Tijdschr Klin Chem Labgeneesk 40, 68–71 (2015).

Metadata

Authors
van den Berg, S. A. A., Thelen, M. H. M., Salden, L. P. W., van Thiel, S. W., & Boonen, K. J. M.
Affiliations
Amphia Ziekenhuis (NL)
Venue
Scientific Reports
Published
2015-03-09
Volume
5
Issue
1
Pages
8875-8875
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2005868517
Cited by
49
References
16
Citations by year
2026: 3 · 2025: 1 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 7 · 2019: 4 · 2018: 4 · 2017: 5 · 2016: 8 · 2015: 3
FWCI
4.91
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
Keywords
glycolysis, blood collection tubes, plasma glucose, sodium fluoride, citrate, EDTA, heparin, pre-analytical variables, diabetes research
MeSH terms
Blood Glucose, Blood Specimen Collection, Citrates, Female, Glycolysis, Humans, Ice, Male, Sodium Fluoride, Artifacts

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: It takes acid, rather than ice, to freeze glucose. https://app.cochat.ai/papers/10.1038/srep08875
The paper
van den Berg, S. A. A., Thelen, M. H. M., Salden, L. P. W., van Thiel, S. W., & Boonen, K. J. M. (2015). It takes acid, rather than ice, to freeze glucose. Scientific Reports. https://doi.org/10.1038/srep08875

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.