The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Exfoliated MoS2 Sheets and Reduced Graphene Oxide-An Excellent and Fast Anode for Sodium-ion Battery
Open accessAbstract
Three dimensional (3D) MoS 2 nanoflowers are successfully synthesized by hydrothermal method. Further, a composite of as prepared MoS 2 nanoflowers and rGO is constructed by simple ultrasonic exfoliation technique. The crystallography and morphological studies have been carried out by XRD, FE-SEM, TEM, HR-TEM and EDS etc. Here, XRD study revealed, a composite of exfoliated MoS 2 with expanded spacing of (002) crystal plane and rGO can be prepared by simple 40 minute of ultrasonic treatment. While, FE-SEM and TEM studies depict, individual MoS 2 nanoflowers with an average diameter of 200 nm are uniformly distributed throughout the rGO surface. When tested as sodium-ion batteries anode material by applying two different potential windows, the composite demonstrates a high reversible specific capacity of 575 mAhg−1 at 100 mAg−1 in between 0.01 V–2.6 V and 218 mAhg−1 at 50 mAg−1 when discharged in a potential range of 0.4 V–2.6 V. As per our concern, the results are one of the best obtained as compared to the earlier published one on MoS 2 based SIB anode material and more importantly this material shows such an excellent reversible Na-storage capacity and good cycling stability without addition of any expensive additive stabilizer, like fluoroethylene carbonate (FEC), in comparison to those in current literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three‐Dimensional Assembly of Single‐Layered MoS2
Wang, P., Sun, H., Ji, Y., Li, W., & Wang, X. (2014) · Advanced Materials · doi:10.1002/adma.201304120 · Cited by 447
Cited by
Hu, Z., Liu, Q., Chou, S., & Dou, S. (2017) · Advanced Materials · doi:10.1002/adma.201700606 · Cited by 911
The Application of Metal Sulfides in Sodium Ion Batteries
Xiao, Y., Lee, S. H., & Sun, Y. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201601329 · Cited by 616
Advanced Carbon‐Based Anodes for Potassium‐Ion Batteries
Wu, X., Chen, Y., Xing, Z., Lam, C. W. K., Pang, S., Zhang, W., & Ju, Z. (2019) · Advanced Energy Materials · doi:10.1002/aenm.201900343 · Cited by 600
Zhao, Y., Wang, L. P., Sougrati, M. T., Feng, Z., Leconte, Y., Fisher, A., Srinivasan, M., & Xu, Z. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201601424 · Cited by 586
Applications of Phosphorene and Black Phosphorus in Energy Conversion and Storage Devices
Pang, J., Bachmatiuk, A., Yin, Y., Trzebicka, B., Zhao, L., Fu, L., Mendes, R. G., Gemming, T., Liu, Z., & Rummeli, M. H. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201702093 · Cited by 518
Metadata
- Authors
- Sahu, T. S., & Mitra, S.
- Venue
- Scientific Reports
- Published
- 2015-07-28
- Volume
- 5
- Issue
- 1
- Pages
- 12571-12571
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2409390695
- Cited by
- 227
- References
- 1
- FWCI
- 13.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.