CoChat

A method for reproducible measurements of serum BDNF: comparison of the performance of six commercial assays

Open access

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

Brain-Derived Neurotrophic Factor (BDNF) has attracted increasing interest as potential biomarker to support the diagnosis or monitor the efficacy of therapies in brain disorders. Circulating BDNF can be measured in serum, plasma or whole blood. However, the use of BDNF as biomarker is limited by the poor reproducibility of results, likely due to the variety of methods used for sample collection and BDNF analysis. To overcome these limitations, using sera from 40 healthy adults, we compared the performance of five ELISA kits (Aviscera-Bioscience, Biosensis, Millipore-ChemiKine TM, Promega-Emax®, R&D-System-Quantikine®) and one multiplexing assay (Millipore-Milliplex®). All kits showed 100% sample recovery and comparable range. However, they exhibited very different inter-assay variations from 5% to 20%. Inter-assay variations were higher than those declared by the manufacturers with only one exception which also had the best overall performance. Dot-blot analysis revealed that two kits selectively recognize mature BDNF, while the others reacted with both pro-BDNF and mature BDNF. In conclusion, we identified two assays to obtain reliable measurements of human serum BDNF, suitable for future clinical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep17989

Cites

Statistics

Figures

Figure 1 BDNF serum levels measured with the indicated ELISA assays. Box plot of serum BDNF concentrations (ng/ml) from healthy volunteers (n = 38–40, see Table 2) represented as mean of two independent measures. The upper line of the box marks the 75th percentile, the middle line is the median value and the lower line specifies the 25th percentile. Whiskers above and below the box indicate the 90th and 10th percentiles, respectively. Dots indicate the outlier values within each group.
Figure 1 BDNF serum levels measured with the indicated ELISA assays. Box plot of serum BDNF concentrations (ng/ml) from healthy volunteers (n = 38–40, see Table 2) represented as mean of two independent measures. The upper line of the box marks the 75th percentile, the middle line is the median value and the lower line specifies the 25th percentile. Whiskers above and below the box indicate the 90th and 10th percentiles, respectively. Dots indicate the outlier values within each group.CC BY · PubMed Central
Figure 2 Inter-assay variation of the BDNF ELISA kits. Scatter plot showing the BDNF values distribution measured by the same operator on two different days using two plates of the same lot for each brand (Day 1 & Day 2). Each dot represents a BDNF value from one subject and the dashed lines link together two assessments of the same subject. The reproducibility was checked performing one-way ANOVA for repeated measures and the P values are specified.
Figure 2 Inter-assay variation of the BDNF ELISA kits. Scatter plot showing the BDNF values distribution measured by the same operator on two different days using two plates of the same lot for each brand (Day 1 & Day 2). Each dot represents a BDNF value from one subject and the dashed lines link together two assessments of the same subject. The reproducibility was checked performing one-way ANOVA for repeated measures and the P values are specified.CC BY · PubMed Central
Figure 3 Inter-assay variation of the Aviscera-Bioscience, Biosensis and Millipore-ChemikineTM kits over a third replica. Scatter plots show the BDNF values distribution measured by the same operator on three different days for each brand. Distributions for Day 1 and Day 2 are the same as Fig. 2, here reported for comparison; distributions for Day 3 were obtained 1 year after Day 2, using a plate of a different lot (serum samples were stored at −80 °C). The reproducibility was checked performing one-way ANOVA for repeated measures and post-hoc Bonferroni correction applied when a significant comparison was found. P values and cumulative CVs expressed in percentage are given.
Figure 3 Inter-assay variation of the Aviscera-Bioscience, Biosensis and Millipore-ChemikineTM kits over a third replica. Scatter plots show the BDNF values distribution measured by the same operator on three different days for each brand. Distributions for Day 1 and Day 2 are the same as Fig. 2, here reported for comparison; distributions for Day 3 were obtained 1 year after Day 2, using a plate of a different lot (serum samples were stored at −80 °C). The reproducibility was checked performing one-way ANOVA for repeated measures and post-hoc Bonferroni correction applied when a significant comparison was found. P values and cumulative CVs expressed in percentage are given.CC BY · PubMed Central
Figure 4 Line-blot for qualitative analysis of anti-BDNF antibodies specificity. (A) The antibodies from each ELISA kit were tested for specificity against pro-BDNF or mature BDNF. The BDNF standards blotted were commercial pro-BDNF (Alomone; 10 pg/lane), mature BDNF (1 and 2 from Alomone and Sigma, respectively; both 1000 pg/lane) and the standard BDNF protein included in each kit (Aviscera-Bioscience and Biosensis: 10 pg/lane; Millipore-ChemiKineTM, Millipore-Milliplex®- and R&D System-Quantikine®: 100 pg/lane; Promega-Emax®: 1000 pg/lane). BSA (1000 pg/lane) was used as a negative control. The mouse monoclonal anti-BDNF antibody, (1:1000; Sigma) was tested as a control. (B) Central region of the same blot shown in A, from an overexposed film to better visualize the reactivity against pro-BDNF. (C) Reactivity of antibodies from Biosensis, Promega-Emax® pAb and Sigma on a dot blot in which the same quantity of pro-BNDF and mature BDNF were spotted (100 pg each). Each antibody from the ELISA kits was used at the dilution suggested by the manufacturer’s instructions. mAb: Promega-Emax® monoclonal capture antibody for plate coating. pAb: Promega-Emax® polyclonal detection antibody.
Figure 4 Line-blot for qualitative analysis of anti-BDNF antibodies specificity. (A) The antibodies from each ELISA kit were tested for specificity against pro-BDNF or mature BDNF. The BDNF standards blotted were commercial pro-BDNF (Alomone; 10 pg/lane), mature BDNF (1 and 2 from Alomone and Sigma, respectively; both 1000 pg/lane) and the standard BDNF protein included in each kit (Aviscera-Bioscience and Biosensis: 10 pg/lane; Millipore-ChemiKineTM, Millipore-Milliplex®- and R&D System-Quantikine®: 100 pg/lane; Promega-Emax®: 1000 pg/lane). BSA (1000 pg/lane) was used as a negative control. The mouse monoclonal anti-BDNF antibody, (1:1000; Sigma) was tested as a control. (B) Central region of the same blot shown in A, from an overexposed film to better visualize the reactivity against pro-BDNF. (C) Reactivity of antibodies from Biosensis, Promega-Emax® pAb and Sigma on a dot blot in which the same quantity of pro-BNDF and mature BDNF were spotted (100 pg each). Each antibody from the ELISA kits was used at the dilution suggested by the manufacturer’s instructions. mAb: Promega-Emax® monoclonal capture antibody for plate coating. pAb: Promega-Emax® polyclonal detection antibody.CC BY · PubMed Central
Figure 5 Graphic summary of BDNF ELISA kit performances. Polar plot showing the kit performances. The black solid line indicates the assessed performances, the dashed line shows those declared by the manufacturers, while bold grey line indicates the best values (100%). Data are from a triplicate experiment for Aviscera-Bioscience, Biosensis and Millipore-ChemiKineTM while from a duplicate for the other kits. See text for a detailed description.
Figure 5 Graphic summary of BDNF ELISA kit performances. Polar plot showing the kit performances. The black solid line indicates the assessed performances, the dashed line shows those declared by the manufacturers, while bold grey line indicates the best values (100%). Data are from a triplicate experiment for Aviscera-Bioscience, Biosensis and Millipore-ChemiKineTM while from a duplicate for the other kits. See text for a detailed description.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 60 · Cited by 263

Metadata

Authors
Polacchini, A., Metelli, G., Francavilla, R., Baj, G., Florean, M., Mascaretti, L. G., & Tongiorgi, E.
Affiliations
University of Trieste (IT)
Corresponding author
Tongiorgi, Enrico
Venue
Scientific Reports
Published
2015-12-10
Volume
5
Issue
1
Pages
17989-17989
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2190736259
Cited by
263
References
60
Citations by year
2026: 19 · 2025: 32 · 2024: 36 · 2023: 36 · 2022: 19 · 2021: 30 · 2020: 30 · 2019: 25 · 2018: 16 · 2017: 8 · 2016: 12
FWCI
5.57
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • ArTS Archivio della ricerca di Trieste (University of Trieste https://www.units.it/) (submittedVersion, cc-by)
  • CINECA IRIS Institutional Research Information System (University of Bari Aldo Moro) (submittedVersion)
Funders
  • Beneficentia Stiftung
  • Ministero dell’Istruzione, dell’Università e della Ricerca (PRIN 2010N8PBAA, 2010N8PBAA)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
brain-derived neurotrophic factor, serum BDNF, ELISA kit comparison, inter-assay variation, reproducibility, proBDNF, mature BDNF, multiplex assay, assay specificity, sample recovery
MeSH terms
Adult, Aged, Enzyme-Linked Immunosorbent Assay, Female, Humans, Male, Middle Aged, Reagent Kits, Diagnostic, Sensitivity and Specificity, Reproducibility of Results, Biomarkers, Brain-Derived Neurotrophic Factor, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A method for reproducible measurements of serum BDNF: comparison of the performance of six commercial assays. https://app.cochat.ai/papers/10.1038/srep17989
The paper
Polacchini, A., Metelli, G., Francavilla, R., Baj, G., Florean, M., Mascaretti, L. G., & Tongiorgi, E. (2015). A method for reproducible measurements of serum BDNF: comparison of the performance of six commercial assays. Scientific Reports. https://doi.org/10.1038/srep17989

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.