Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids
Open accessThe DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index.
Abstract
Photoacoustic Doppler velocimetry provides a major opportunity to overcome limitations of existing blood flow measuring methods. By enabling measurements with high spatial resolution several millimetres deep in tissue, it could probe microvascular blood flow abnormalities characteristic of many different diseases. Although previous work has demonstrated feasibility in solid phantoms, measurements in blood have proved significantly more challenging. This difficulty is commonly attributed to the requirement that the absorber spatial distribution is heterogeneous relative to the minimum detectable acoustic wavelength. By undertaking a rigorous study using blood-mimicking fluid suspensions of 3 μm absorbing microspheres, it was discovered that the perceived heterogeneity is not only limited by the intrinsic detector bandwidth; in addition, bandlimiting due to spatial averaging within the detector field-of-view also reduces perceived heterogeneity and compromises velocity measurement accuracy. These detrimental effects were found to be mitigated by high-pass filtering to select photoacoustic signal components associated with high heterogeneity. Measurement under-reading due to limited light penetration into the flow vessel was also observed. Accurate average velocity measurements were recovered using “range-gating”, which furthermore maps the cross-sectional velocity profile. These insights may help pave the way to deep-tissue non-invasive mapping of microvascular blood flow using photoacoustic methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures











Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“This study builds upon the foundational research on PADF, where the speed of flowing particles having parabolic flow distribution in a cylindrical tube or vessel is measured from their Doppler shift of frequencies [26,27,28,29,30,31,32].”
From Multiwavelength Photoacoustic Doppler Flowmetry of Living Microalgae Cells (2024) · cites this paper as [26]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
Treeby, B. E., & Cox, B. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3360308 · Cited by 2,337
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Self-citationA review of optical coherence tomography angiography (OCTA)
de Carlo, T. E., Romano, A., Waheed, N. K., & Duker, J. S. (2015) · International Journal of Retina and Vitreous · doi:10.1186/s40942-015-0005-8 · Cited by 1,126
Doppler Ultrasound: Physics, Instrumentation and Signal Processing
Evans, D. H. (2000) · Cited by 364
Hein, I. A., & O'Brien, W. D. (1993) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.212556 · Cited by 309
Single-cell label-free photoacoustic flowoxigraphy in vivo
Wang, L., Maslov, K., & Wang, L. V. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1215578110 · Cited by 218
‘ Go with the flow ’: A review of methods and advancements in blood flow imaging
Daly, S. M., & Leahy, M. J. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200071 · Cited by 136
The role of blood flow in determining the sites of atherosclerotic plaques
Warboys, C. M., Amini, N., Luca, A. D., & Evans, P. C. (2011) · F1000 Medicine Reports · doi:10.3410/m3-5 · Cited by 121
The Relationship between Tumor Blood Flow, Angiogenesis, Tumor Hypoxia, and Aerobic Glycolysis
Østergaard, L., Tietze, A., Nielsen, T., Drasbek, K. R., Mouridsen, K., Jespersen, S. N., & Horsman, M. R. (2013) · Cancer Research · doi:10.1158/0008-5472.can-13-0964 · Cited by 113
The Effect of Diabetes on Blood Flow Properties
McMillan, D. E. (1983) · Diabetes · doi:10.2337/diab.32.2.s56 · Cited by 106
Research works printed but not linked: 3
- Patel, B. R. In Fundamentals of Fluid Mechanics (eds. Schetz, J. A. & Fuhs, A. E. ) 486 (John Wiley & Sons, 1999).
- Munson, B. R., Young, D. F. & Okiishi, T. H. In Fundamentals of Fluid Mechanics 327–329 (John Wiley & Sons, 2006).
- White, F. M. In Fluid Mechanics 341–342 (McGraw-Hill, 1999).
Cited by
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Super Wide-Field Photoacoustic Microscopy of Animals and Humans In Vivo
Baik, J. W., Kim, J. Y., Cho, S., Choi, S., Kim, J., & Kim, C. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2938518 · Cited by 125
Super-resolution photoacoustic imaging via flow-induced absorption fluctuations
Chaigne, T., Arnal, B., Вилов, С. А., Bossy, E., & Katz, O. (2017) · Optica · doi:10.1364/optica.4.001397 · Cited by 80
Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler
Brunker, J., & Beard, P. C. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.002789 · Cited by 38
Self-citationElectromagnetic–Acoustic Sensing for Biomedical Applications
Liu, S., Zhang, R., Zheng, Z., & Zheng, Y. (2018) · Sensors · doi:10.3390/s18103203 · Cited by 34
Metadata
- Authors
- Brunker, J., & Beard, P.
- Affiliations
- University College London (GB)
- Corresponding author
- Brunker, Joanna
- ORCID
- Beard, Paul
- Venue
- Scientific Reports
- Published
- 2016-02-19
- Volume
- 6
- Issue
- 1
- Pages
- 20902-20902
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC4759580
- OpenAlex
- W2338716815
- Cited by
- 32
- References
- 22
- Citations by year
- 2026: 1 · 2024: 5 · 2023: 2 · 2022: 4 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 4 · 2017: 2 · 2016: 4
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Update notices
- erratum (2016-04-20)
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- European Commission (FP7 ICT, 317744)
- Engineering and Physical Sciences Research Council (EP/H005536/1, FP7 ICT, Contract 317744)
- FP7 Information and Communication Technologies (317744)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- blood flow measurement, blood-mimicking fluid, microspheres, detector bandwidth, spatial averaging, high-pass filtering, range gating, light penetration depth, microvascular blood flow, deep tissue imaging
- MeSH terms
- Acoustics, Algorithms, Blood Flow Velocity, Humans, Models, Cardiovascular, Laser-Doppler Flowmetry, Phantoms, Imaging, Photoacoustic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids. https://app.cochat.ai/papers/10.1038/srep20902
- The paper
- Brunker, J., & Beard, P. (2016). Acoustic resolution photoacoustic Doppler velocimetry in blood-mimicking fluids. Scientific Reports. https://doi.org/10.1038/srep20902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.