Longitudinal, label-free, quantitative tracking of cell death and viability in a 3D tumor model with OCT
Open accessThe DOI matches its Crossref record.
Abstract
Three-dimensional in vitro tumor models are highly useful tools for studying tumor growth and treatment response of malignancies such as ovarian cancer. Existing viability and treatment assessment assays, however, face shortcomings when applied to these large, complex and heterogeneous culture systems. Optical coherence tomography (OCT) is a noninvasive, label-free, optical imaging technique that can visualize live cells and tissues over time with subcellular resolution and millimeters of optical penetration depth. Here, we show that OCT is capable of carrying out high-content, longitudinal assays of 3D culture treatment response. We demonstrate the usage and capability of OCT for the dynamic monitoring of individual and combination therapeutic regimens in vitro, including both chemotherapy drugs and photodynamic therapy (PDT) for ovarian cancer. OCT was validated against the standard LIVE/DEAD Viability/Cytotoxicity Assay in small tumor spheroid cultures, showing excellent correlation with existing standards. Importantly, OCT was shown to be capable of evaluating 3D spheroid treatment response even when traditional viability assays failed. OCT 3D viability imaging revealed synergy between PDT and the standard-of-care chemotherapeutic carboplatin that evolved over time. We believe the efficacy and accuracy of OCT in vitro drug screening will greatly contribute to the field of cancer treatment and therapy evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Barbosa, M. A. G., Xavier, C. P. R., Pereira, R. F., Petrikaitė, V., & Vasconcelos, M. H. (2021) · Cancers · doi:10.3390/cancers14010190 · Cited by 285
“Label-dependent methods for viability assessment, such as fluorescence imaging and luminescence assays, lack sensitivity when analyzing large spheroid cultures with hypoxic and acidic compartments, due to the low penetration depth [116].”
BackgroundMethodInfluentialPresent Application and Perspectives of Organoid Imaging Technology
Fei, K., Zhang, J., Yuan, J., & Xiao, P. (2022) · Bioengineering · doi:10.3390/bioengineering9030121 · Cited by 65
“For example, the in-place motions (motility) of mammary epithelial cells within organoids was evaluated and quantified [168], to analyze the viability of tumor organoids [169], etc.”
BackgroundMicrofluidic system for modelling 3D tumour invasion into surrounding stroma and drug screening
Du, Z., Mi, S., Yi, X., Xu, Y., & Sun, W. (2018) · Biofabrication · doi:10.1088/1758-5090/aac70c · Cited by 42
Dong, Y., Li, G., Wang, L., Cao, L., Li, Y., & Zhao, W. (2020) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2020.112015 · Cited by 20
Metadata
- Authors
- Jung, Y., Klein, O. J., Wang, H., & Evans, C. L.
- Venue
- Scientific Reports
- Published
- 2016-06-01
- Volume
- 6
- Issue
- 1
- Pages
- 27017-27017
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2462114633
- Cited by
- 32
- References
- 0
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.