The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fully Automatic System for Accurate Localisation and Analysis of Cephalometric Landmarks in Lateral Cephalograms
Open accessAbstract
Cephalometric tracing is a standard analysis tool for orthodontic diagnosis and treatment planning. The aim of this study was to develop and validate a fully automatic landmark annotation (FALA) system for finding cephalometric landmarks in lateral cephalograms and its application to the classification of skeletal malformations. Digital cephalograms of 400 subjects (age range: 7–76 years) were available. All cephalograms had been manually traced by two experienced orthodontists with 19 cephalometric landmarks, and eight clinical parameters had been calculated for each subject. A FALA system to locate the 19 landmarks in lateral cephalograms was developed. The system was evaluated via comparison to the manual tracings, and the automatically located landmarks were used for classification of the clinical parameters. The system achieved an average point-to-point error of 1.2 mm, and 84.7% of landmarks were located within the clinically accepted precision range of 2.0 mm. The automatic landmark localisation performance was within the inter-observer variability between two clinical experts. The automatic classification achieved an average classification accuracy of 83.4% which was comparable to an experienced orthodontist. The FALA system rapidly and accurately locates and analyses cephalometric landmarks in lateral cephalograms, and has the potential to significantly improve the clinical work flow in orthodontic treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steiner, C. C. (1953) · American Journal of Orthodontics · doi:10.1016/0002-9416(53)90082-7 · Cited by 1,365
Wang, C.-W., Huang, C.-T., Hsieh, M.-C., Li, C.-H., Chang, S.-W., Li, W.-C., Vandaele, R., Maree, R., Jodogne, S., Geurts, P., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2412951 · Cited by 235
Self-citation
Cited by
Hung, K., Montalvao, C., Tanaka, R., Kawai, T., & Bornstein, M. M. (2020) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20190107 · Cited by 387
Integrating spatial configuration into heatmap regression based CNNs for landmark localization
Payer, C., Štern, D., Bischof, H., & Urschler, M. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.007 · Cited by 365
Metadata
- Authors
- Lindner, C., Wang, C.-W., Huang, C.-T., Li, C.-H., Chang, S.-W., & Cootes, T. F.
- Venue
- Scientific Reports
- Published
- 2016-09-20
- Volume
- 6
- Issue
- 1
- Pages
- 33581-33581
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2522168735
- Cited by
- 225
- References
- 2
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully Automatic System for Accurate Localisation and Analysis of Cephalometric Landmarks in Lateral Cephalograms. https://app.cochat.ai/papers/10.1038/srep33581
- The paper
- Lindner, C., Wang, C.-W., Huang, C.-T., Li, C.-H., Chang, S.-W., & Cootes, T. F. (2016). Fully Automatic System for Accurate Localisation and Analysis of Cephalometric Landmarks in Lateral Cephalograms. Scientific Reports. https://doi.org/10.1038/srep33581
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.