The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Novel amperometric glucose biosensor based on MXene nanocomposite
Open accessAbstract
A biosensor platform based on Au/MXene nanocomposite for sensitive enzymatic glucose detection is reported. The biosensor leverages the unique electrocatalytic properties and synergistic effects between Au nanoparticles and MXene sheets. An amperometric glucose biosensor is fabricated by the immobilization of glucose oxidase (GOx) enzyme on Nafion solubilized Au/ MXene nanocomposite over glassy carbon electrode (GCE). The biomediated Au nanoparticles play a significant role in facilitating the electron exchange between the electroactive center of GOx and the electrode. The GOx/Au/MXene/Nafion/GCE biosensor electrode displayed a linear amperometric response in the glucose concentration range from 0.1 to 18 mM with a relatively high sensitivity of 4.2 μAmM−1 cm−2 and a detection limit of 5.9 μM (S/N = 3). Furthermore, the biosensor exhibited excellent stability, reproducibility and repeatability. Therefore, the Au/MXene nanocomposite reported in this work is a potential candidate as an electrochemical transducer in electrochemical biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Cited by
Jiang, X., Kuklin, A. V., Baev, A., Ge, Y., Ågren, H., Zhang, H., & Prasad, P. N. (2020) · Physics Reports · doi:10.1016/j.physrep.2019.12.006 · Cited by 914
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Recent advance in MXenes: A promising 2D material for catalysis, sensor and chemical adsorption
Zhu, J., Ha, E., Zhao, G., Zhou, Y., Huang, D., Yue, G., Hu, L., Sun, N., Wang, Y., Lee, L. Y. S., et al. (2017) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.09.012 · Cited by 659
Two-Dimensional Ti3C2 MXene for High-Resolution Neural Interfaces
Driscoll, N., Richardson, A. G., Maleski, K., Anasori, B., Adewole, O., Lelyukh, P., Escobedo, L., Cullen, D. K., Lucas, T. H., Gogotsi, Y., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b06014 · Cited by 312
Lorencova, L., Bertok, T., Filip, J., Jerigova, M., Velic, D., Kasak, P., Mahmoud, K. A., & Tkac, J. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.02.124 · Cited by 282
Metadata
- Authors
- Rakhi, R. B., Nayak, P., Xia, C., & Alshareef, H. N.
- Venue
- Scientific Reports
- Published
- 2016-11-10
- Volume
- 6
- Issue
- 1
- Pages
- 36422-36422
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2555857612
- Cited by
- 448
- References
- 1
- FWCI
- 12.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel amperometric glucose biosensor based on MXene nanocomposite. https://app.cochat.ai/papers/10.1038/srep36422
- The paper
- Rakhi, R. B., Nayak, P., Xia, C., & Alshareef, H. N. (2016). Novel amperometric glucose biosensor based on MXene nanocomposite. Scientific Reports. https://doi.org/10.1038/srep36422
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.