CoChat

Chip-scale cavity optomechanics in lithium niobate

Open access
Jiang, Wei C., Lin, Qiang · 2016 · Scientific Reports

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

We develop a chip-scale cavity optomechanical system in single-crystal lithium niobate that exhibits high optical quality factors and a large frequency-quality product as high as 3.6 × 10 12 Hz at room temperature and atmosphere. The excellent optical and mechanical properties together with the strong optomechanical coupling allow us to efficiently excite the coherent regenerative optomechanical oscillation operating at 375 MHz with a threshold power of 174 μ W in the air. The demonstrated lithium niobate optomechanical device enables great potential for achieving electro-optic-mechanical hybrid systems for broad applications in sensing, metrology, and quantum physics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep36920

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (a) SEM image of a fabricated LN microdisk with a radius of 6 μm. The slant angle of the sidewall is around 45 degree. Inset: simulated optical mode profile of the fundamental quasi-transverse-electric (quasi-TE) mode by FEM. (b) Simulated mechanical frequency of the fundamental RBM as a function of radius for the LN microdisk with a thickness of 400 nm. Inset: Simulated mechanical displacement profile of the fundamental RBM by FEM (For LN, Young’s modulus E = 181 GPa and mass density ρ = 4640 kg/m3). (c) Experimental setup for optomechanical measurement. MZI: Mach-Zehnder interferometer; VOA: variable optical attenuator; ESA: electrical spectrum analyzer.
Figure 1 (a) SEM image of a fabricated LN microdisk with a radius of 6 μm. The slant angle of the sidewall is around 45 degree. Inset: simulated optical mode profile of the fundamental quasi-transverse-electric (quasi-TE) mode by FEM. (b) Simulated mechanical frequency of the fundamental RBM as a function of radius for the LN microdisk with a thickness of 400 nm. Inset: Simulated mechanical displacement profile of the fundamental RBM by FEM (For LN, Young’s modulus E = 181 GPa and mass density ρ = 4640 kg/m3). (c) Experimental setup for optomechanical measurement. MZI: Mach-Zehnder interferometer; VOA: variable optical attenuator; ESA: electrical spectrum analyzer.CC BY · PubMed Central
Figure 2 The cavity transmission of the LN microdisk. The insets show detailed transmission spectra for the fundamental quasi-TE modes at 1498 nm and 1529 nm, respectively, with a theoretical fitting (red).
Figure 2 The cavity transmission of the LN microdisk. The insets show detailed transmission spectra for the fundamental quasi-TE modes at 1498 nm and 1529 nm, respectively, with a theoretical fitting (red).CC BY · PubMed Central
Figure 3 (a) Optically transduced RF spectrum (blue curve) of the cavity transmission showing the fundamental and second-order RBMs at 375.9 MHz and 1.029 GHz, respectively. The gray trace shows the noise background of the high-speed photo-detector. (b,c) Detailed thermal noise spectra with Lorentzian fitting for the fundamental and second-order RBMs, respectively.
Figure 3 (a) Optically transduced RF spectrum (blue curve) of the cavity transmission showing the fundamental and second-order RBMs at 375.9 MHz and 1.029 GHz, respectively. The gray trace shows the noise background of the high-speed photo-detector. (b,c) Detailed thermal noise spectra with Lorentzian fitting for the fundamental and second-order RBMs, respectively.CC BY · PubMed Central
Figure 4 (a) The mechanical damp rate as a function of optical drop power with a linear fitting in blue. (b) Intensity image of the measured RF spectrum versus normailzed laser detuning at the blue-detuning side. Measured (c) mechanical damp rate and (d) mechanical frequency versus normalized laser detuning compared with the theoretical curves.
Figure 4 (a) The mechanical damp rate as a function of optical drop power with a linear fitting in blue. (b) Intensity image of the measured RF spectrum versus normailzed laser detuning at the blue-detuning side. Measured (c) mechanical damp rate and (d) mechanical frequency versus normalized laser detuning compared with the theoretical curves.CC BY · PubMed Central
Figure 5 (a) RF Spectrum of the fundamental RBM at various optical drop powers showing optomechanical oscillation. The inset shows the detailed oscillation spectrum with a Lorentzian fitting (red). (b) The self-oscillation spectrum exhibiting generation of a series of harmonics. (c) The normalized mechanical energy as a function of optical drop power. The red line is a linear fit to data above threshold. The inset shows the theoretical drop power threshold for our device as a function of normalized laser detuning. The dashed line indicates the detuning for the measurement.
Figure 5 (a) RF Spectrum of the fundamental RBM at various optical drop powers showing optomechanical oscillation. The inset shows the detailed oscillation spectrum with a Lorentzian fitting (red). (b) The self-oscillation spectrum exhibiting generation of a series of harmonics. (c) The normalized mechanical energy as a function of optical drop power. The red line is a linear fit to data above threshold. The inset shows the theoretical drop power threshold for our device as a function of normalized laser detuning. The dashed line indicates the detuning for the measurement.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Cited by

Metadata

Authors
Jiang, W. C., & Lin, Q.
Affiliations
University of Rochester (US)
Corresponding author
Lin, Qiang
Venue
Scientific Reports
Published
2016-11-14
Volume
6
Issue
1
Pages
36920-36920
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2963681268
Cited by
56
References
44
Citations by year
2026: 4 · 2025: 5 · 2024: 5 · 2023: 4 · 2022: 2 · 2021: 8 · 2020: 3 · 2019: 7 · 2018: 8 · 2017: 8
FWCI
3.63
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • National Science Foundation (1509749)
  • Shanghai Jiao Tong University (2016GZKF0JT001)
  • State Key Laboratory of Advanced Optical Communication Systems and Networks
  • Division of Electrical, Communications and Cyber Systems
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Acoustic Wave Resonator Technologies
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
Keywords
cavity optomechanics, lithium niobate, optical quality factor, optomechanical coupling, threshold power, room-temperature operation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.