The DOI matches its Crossref record.
Correction of Matrix Effects in Quantitative Elemental Analysis With Laser Ablation Optical Emission Spectrometry
Abstract
A new approach to the quantification of the optical emission signals from a laser produced plasma in air at atmospheric pressure is described. It is based on a simple analytical model giving intensity of the emission lines as a function of the vaporized mass and the plasma excitation temperature. Under the hypothesis of a stoichiometric ablation process, these two parameters are presumed to be responsible for the matrix effects observed when the composition of the sample is changed. Under the experimental conditions chosen it is demonstrated that the acoustic signal emitted by the plasma is proportional to the vaporized mass and that the excitation plasma temperature can be controlled using the line ratio of a given element chosen as a ‘temperature sensor’. Normalization of the emission signals by these two parameters allows for an efficient correction of the matrix effects. Results obtained on a series of aluminium alloys, steel and brass samples demonstrate, for the first time, the possibility of matrix independent analysis with LA-OES with an accuracy of a few percent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hahn, D. W., & Omenetto, N. (2012) · Applied Spectroscopy · doi:10.1366/11-06574 · Cited by 1,497
New Procedure for Quantitative Elemental Analysis by Laser-Induced Plasma Spectroscopy
Ciucci, A., Corsi, M., Palleschi, V., Rastelli, S., Salvetti, A., & Tognoni, E. (1999) · Applied Spectroscopy · doi:10.1366/0003702991947612 · Cited by 879
Aragón, C., & Aguilera, J. A. (2008) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.05.010 · Cited by 636
Winefordner, J. D., Gornushkin, I. B., Correll, T., Gibb, E., Smith, B. W., & Omenetto, N. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b400355c · Cited by 486
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Tognoni, E., Cristoforetti, G., Legnaioli, S., & Palleschi, V. (2010) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2009.11.006 · Cited by 465
Metadata
- Authors
- CHALÉARD, C., MAUCHIEN, P., ANDRE, N., UEBBING, J., L. LACOUR, J., & GEERTSEN, C.
- Venue
- J. Anal. At. Spectrom.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1997
- Volume
- 12
- Issue
- 2
- Pages
- 183-188
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2061151786
- Cited by
- 190
- References
- 0
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correction of Matrix Effects in Quantitative Elemental Analysis With Laser Ablation Optical Emission Spectrometry. https://app.cochat.ai/papers/10.1039/a604456e
- The paper
- CHALÉARD, C., MAUCHIEN, P., ANDRE, N., UEBBING, J., L. LACOUR, J., & GEERTSEN, C. (1997). Correction of Matrix Effects in Quantitative Elemental Analysis With Laser Ablation Optical Emission Spectrometry. J. Anal. At. Spectrom. https://doi.org/10.1039/a604456e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.