The DOI matches its Crossref record.
Calixpyrroles
Abstract
The calix[4]pyrroles are a class of old but new heterocalixarene analogues that show interesting anion and neutral substrate binding properties. Calix[4]pyrroles are easy to make and functionalize. As such, they have been employed in the production of separation media for anionic and neutral species. Calixpyrroles also provide useful precursors for the generation of novel calixpyridinopyrroles and calixpyridines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Nguyen, B. T., & Anslyn, E. V. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.04.009 · Cited by 668
Development of Ion Chemosensors Based on Porphyrin Analogues
Ding, Y., Zhu, W.-H., & Xie, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00021 · Cited by 653
Transition metal and organometallic anion complexation agents
Beer, P. D., & Hayes, E. J. (2003) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(02)00303-x · Cited by 534
Erkennung und Nachweis von Anionen: gegenwärtiger Stand und Perspektiven
Beer, P. D., & Gale, P. A. (2001) · Angewandte Chemie · doi:10.1002/1521-3757(20010202)113:3<502::aid-ange502>3.0.co;2-a · Cited by 513
Self-citationFigure Eights, Möbius Bands, and More: Conformation and Aromaticity of Porphyrinoids
Stępień, M., Sprutta, N., & Latos‐Grażyński, L. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201003353 · Cited by 481
Gale, P. A., Anzenbacher Jr., P., & Sessler, J. L. (2001) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(01)00346-0 · Cited by 403
Self-citationMacrocycles as Ion Pair Receptors
He, Q., Vargas-Zúñiga, G. I., Kim, S. H., Kim, S. K., & Sessler, J. L. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00734 · Cited by 319
Self-citationIndole‐Based Macrocycles as a Class of Receptors for Anions
Chang, K., Moon, D., Lah, M. S., & Jeong, K. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200503121 · Cited by 275
Molecular recognition of organic ammonium ions in solution using synthetic receptors
Späth, A., & König, B. (2010) · Beilstein Journal of Organic Chemistry · doi:10.3762/bjoc.6.32 · Cited by 255
Amino acid containing anion receptors
Kubik, S. (2009) · Chem. Soc. Rev. · doi:10.1039/b810531f · Cited by 255
Metadata
- Authors
- Gale, P. A., Sessler, J. L., & Král, V.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1998
- Issue
- 1
- Pages
- 1-8
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W4253604628
- Cited by
- 392
- References
- 0
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.