The DOI matches its Crossref record.
Application of a frequency quintupled Nd:YAG source (λ=213 nm) for laser ablation inductively coupled plasma mass spectrometric analysis of minerals
Abstract
This paper reports the use a frequency quintupled Nd:YAG laser (λ=213 nm) for laser ablation of minerals for ICP-MS analysis. The fifth harmonic was produced by in-house modification to an existing frequency quadrupled Nd:YAG laser (λ=266 nm), using commercially available optical components. The maximum pulse energy of the 213 nm output is 7.5 mJ per pulse, based on an output of 350 mJ per pulse at 1064 nm. The pulse energy is controlled and attenuated by a wave plate and MgF2 polariser combination. The laser sampling system was coupled to an enhanced sensitivity ICP-MS system. Comparison of time resolved signals for extended analyses of several materials using 213 and 266 nm for ablation demonstrates that (1) 213 nm laser ablation greatly reduces the incidence of catastrophic ablation of strongly cleaved minerals in thin section, owing to higher absorption; (2) in each case, 213 nm laser ablation produces a longer, flatter, higher intensity signal than conventional 266 nm laser ablation, suggesting a larger volume of transportable particulate is produced; and (3) inter-element fractionation is reduced during analysis using the 213 nm laser ablation system. This study is the first reported use of frequency quintupled laser ablation microprobe (LAM)–ICP-MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Composition of altered oceanic crust at ODP Sites 801 and 1149
Kelley, K. A., Plank, T., Ludden, J., & Staudigel, H. (2003) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2002gc000435 · Cited by 573
Present Trends and the Future of Zircon in Geochronology: Laser Ablation ICPMS
Kosler, J. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530243 · Cited by 324
Guillong, M., Horn, I., & Günther, D. (2003) · J. Anal. At. Spectrom. · doi:10.1039/b305434a · Cited by 282
Review of the State-of-the-Art of Laser Ablation Inductively Coupled Plasma Mass Spectrometry
Koch, J., & Günther, D. (2011) · Applied Spectroscopy · doi:10.1366/11-06255 · Cited by 270
A comparison of nanosecond and femtosecond laser-induced plasma spectroscopy of brass samples
Margetic, V, Pakulev, A., Stockhaus, A., Bolshov, M., Niemax, K., & Hergenröder, R. (2000) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(00)00275-5 · Cited by 255
Anomalously Metal-Rich Fluids Form Hydrothermal Ore Deposits
Wilkinson, J. J., Stoffell, B., Wilkinson, C. C., Jeffries, T. E., & Appold, M. S. (2009) · Science · doi:10.1126/science.1164436 · Cited by 199
Self-citation
Metadata
- Authors
- E. Jeffries, T., E. Jackson, S., & P. Longerich, H.
- Venue
- J. Anal. At. Spectrom.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1998
- Volume
- 13
- Issue
- 9
- Pages
- 935-940
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2009326378
- Cited by
- 168
- References
- 0
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.