The DOI matches its Crossref record.
The determination of copper, zinc, cadmium and lead in urine by high resolution ICP-MS
Open accessAbstract
High resolution ICP-MS was used to determine Cu, Zn, Cd and Pb in urine. The effect of sample dilution, preparation method and choice of internal standard were assessed. Sample dilution (1+9) with In as the internal standard was found to offer an acceptable compromise between analytical accuracy and sample throughput. A spectral resolution of 3000 was used to separate Cu and Zn isotopes from interferences commonly found in biological matrices, while a resolution of 300, offering increased sensitivity and lower detection limits, was used for Cd and Pb. The accuracy and precision of the analytical method were evaluated using two Bio-Rad Lyphochek standard urines. The concentrations of Cu, Zn, Cd and Pb in Bio-Rad Level 1 reference urine were determined by external calibration and were found to agree to within 0-17% of recommended values (Cu 48, Zn 710, Cd 6.5 and Pb 14.3 ng g –1 ). Closer agreement of 0-7% was found for Bio-Rad Level 2 reference urine (Cu 63, Zn 1057, Cd 12.3 and Pb 69 ng g –1 ). Forty-two urine samples from seven workers occupationally exposed to Cd were analysed and the results were compared with those obtained from 11 samples collected from four non-exposed volunteers. Similar average concentrations of Cu and Zn were found in both groups when the results were normalised to creatinine levels. Workers exposed to Cd were found to have an average urine Cd concentration elevated approximately 7-8-fold over that measured for the control group (about 2.2 compared with about 0.3 ng g –1 , or 1.7 and 0.2 μg per gram of creatinine when normalised). Urinary levels of Pb were slightly increased in the cadmium exposed workers (about 6 compared with about 4 ng g –1 ).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions
Kim, H. N., Ren, W. X., Kim, J. S., & Yoon, J. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15245a · Cited by 2,253
Aragay, G., Pons, J., & Merkoçi, A. (2011) · Chemical Reviews · doi:10.1021/cr100383r · Cited by 1,396
Fluorescent carbon nanoparticles for the fluorescent detection of metal ions
Guo, Y., Zhang, L., Zhang, S., Yang, Y., Chen, X., & Zhang, M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.018 · Cited by 390
Biomonitoring of 30 trace elements in urine of children and adults by ICP-MS
Heitland, P., & Köster, H. D. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.09.013 · Cited by 346
Small molecular fluorescent probes for the detection of lead, cadmium and mercury ions
Chen, S.-Y., Li, Z., Li, K., & Yu, X.-Q. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213691 · Cited by 283
Metadata
- Authors
- Townsend, A. T., Miller, K. A., McLean, S., & Aldous, S.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1998
- Volume
- 13
- Issue
- 11
- Pages
- 1213-1219
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2070387421
- Cited by
- 199
- References
- 0
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The determination of copper, zinc, cadmium and lead in urine by high resolution ICP-MS. https://app.cochat.ai/papers/10.1039/a805021j
- The paper
- Townsend, A. T., Miller, K. A., McLean, S., & Aldous, S. (1998). The determination of copper, zinc, cadmium and lead in urine by high resolution ICP-MS. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/a805021j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.