The DOI matches its Crossref record.
Cathodic dissolution in the electrocoagulation process using aluminium electrodes
Abstract
All the authors working with aluminium electrodes in the electrocoagulation process have shown that a dissolution occurs at the cathode. This result cannot be explained by the electrochemical process in which only the anodes should be dissolved. The most probable reaction is a chemical attack by hydroxyl ions (generated during water reduction) on the aluminium cathode but nobody has proved it in the framework of the electrocoagulation process. So we are interested in determining what kind of reactions occurs at the cathode. For that, we have elaborated a batch pilot apparatus divided into two compartments, allowing measurement of gas formation taking place only in one compartment. The gases measurements were performed by mass spectrometry with helium as carrier gas. To validate our experimental protocol, the first experiments have been done with a stainless steel cathode: in this case, the results have indicated that the amount of created hydrogen is in good agreement with the values calculated using the second Faraday's law. The experiments realised with an aluminium cathode have shown that the hydrogen formation, in these conditions, was higher than those observed with the stainless steel cathode. All our investigations enable us to propose that with an aluminium cathode, hydrogen formation can be separated into two phenomena. The first one is due to an electrochemical reaction (water reduction), and the second one arises from a chemical reaction explaining the dissolution observed at the cathode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Martínez-Huitle, C. A., & Brillas, E. (2009) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2008.09.017 · Cited by 2,250
Treatment of textile wastewaters by electrocoagulation using iron and aluminum electrodes
Kobya, M., Can, O. T., & Bayramoglu, M. (2003) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(03)00102-x · Cited by 839
Treatment of electroplating wastewater containing Cu2+, Zn2+ and Cr(VI) by electrocoagulation
ADHOUM, N., MONSER, L., BELLAKHAL, N., & BELGAIED, J. (2004) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2004.04.018 · Cited by 569
Operating cost analysis of electrocoagulation of textile dye wastewater
Bayramoglu, M., Kobya, M., Can, O. T., & Sozbir, M. (2004) · Separation and Purification Technology · doi:10.1016/j.seppur.2003.09.002 · Cited by 449
Treatment of the textile wastewater by combined electrocoagulation
Can, O. T., Kobya, M., Demirbas, E., & Bayramoglu, M. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2005.05.022 · Cited by 411
Metadata
- Authors
- Picard, T., Cathalifaud-Feuillade, G., Mazet, M., & Vandensteendam, C.
- Venue
- Journal of Environmental Monitoring
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2000
- Volume
- 2
- Issue
- 1
- Pages
- 77-80
- ISSN
- 1464-0325 (ISSN-L)
- 1464-0333
- OpenAlex
- W2074563989
- Cited by
- 204
- References
- 0
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cathodic dissolution in the electrocoagulation process using aluminium electrodes. https://app.cochat.ai/papers/10.1039/a908248d
- The paper
- Picard, T., Cathalifaud-Feuillade, G., Mazet, M., & Vandensteendam, C. (2000). Cathodic dissolution in the electrocoagulation process using aluminium electrodes. Journal of Environmental Monitoring. https://doi.org/10.1039/a908248d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.