The DOI matches its Crossref record.
Copper(II)-selective electrodes based on macrocyclic compounds
Abstract
Poly(vinyl chloride) based membranes of 5,7,7,12,14,14-hexamethyl-1,4,8,11-tetraazacyclotetradeca-4,11-diene diperchlorate and 3,5,7,7,10,12,14,14-octamethyl-1,4,8,11-tetraazacyclotetradeca-4,11-diene diperchlorate with dibutyl phthalate (DBP) and dioctyl phthalate (DOP) as plasticizing solvent mediator show a Nernstian response for Cu2+ ions over a wide concentration range (1 × 10–5–1 × 10–1 mol l–1) between pH 1.9 and 5.2. These electrodes have been found to be chemically inert and of adequate stability, with a response time less than 30 s. The electrodes are selective over a large number of cations, including HgII, and anions such as Cl– and Br– cause no interference. These electrodes work satisfactorily in partially non-aqueous media and have been used as indicator electrodes in potentiometric titrations of Cu2+ with EDTA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mohammadi, N., Khani, H., Gupta, V. K., Amereh, E., & Agarwal, S. (2011) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.06.067 · Cited by 818
Self-citationElectrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes
Gupta, V. K., Ganjali, M. R., Norouzi, P., Khani, H., Nayak, A., & Agarwal, S. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.589773 · Cited by 580
Self-citation
Metadata
- Authors
- Jain, A. K., Gupta, V. K., Sahoo, B. B., & Singh, L. P.
- Venue
- Analytical Proceedings including Analytical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1995
- Volume
- 32
- Issue
- 3
- Pages
- 99
- ISSN
- 0144-557X (ISSN-L)
- OpenAlex
- W2129074529
- Cited by
- 219
- References
- 0
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Copper(II)-selective electrodes based on macrocyclic compounds. https://app.cochat.ai/papers/10.1039/ai9953200099
- The paper
- Jain, A. K., Gupta, V. K., Sahoo, B. B., & Singh, L. P. (1995). Copper(II)-selective electrodes based on macrocyclic compounds. Analytical Proceedings including Analytical Communications. https://doi.org/10.1039/ai9953200099
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.