The DOI matches its Crossref record.
Neutral carrier and organic resin based membranes as sensors for uranyl ions
Abstract
Uranyl ion selective electrodes have been constructed from poly(vinyl chloride) matrix membranes containing neutral carrier, 2,3,11,12-dicyclohexano-1,4,7,10,13,16-hexaoxacyclooctadecane and organic resin, 2,4-dihydroxypropiophenoneoxime–formaldehyde using dibutyl phthalate and dioctyl phthalate as plasticizing solvent mediators. These electrodes demonstrate linear response to UO2+2 ions in the concentration range 10–5–10–1 mol l–1 with a Nernstian or near Nernstian slope at pH 3. The electrodes are inert towards acids, salt solutions and non-aqueous media for a period of 3 months and exhibit a response time as fast as 30 s. The electrodes with plasticizers have been found to be better compared with electrodes without plasticizers. The electrodes are sufficiently selective over a large number of bivalent and trivalent cations including calcium, iron(III) and copper(II), with selectivity coefficient values of the order of 0.01 for bivalent and 0.001 for trivalent cations. Monovalent ions cause interference at higher concentrations with selectivity coefficient values of the order of 0.1. The electrodes work satisfactorily in a partially non-aqueous medium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mohammadi, N., Khani, H., Gupta, V. K., Amereh, E., & Agarwal, S. (2011) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.06.067 · Cited by 818
Self-citationElectrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes
Gupta, V. K., Ganjali, M. R., Norouzi, P., Khani, H., Nayak, A., & Agarwal, S. (2011) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2011.589773 · Cited by 580
Self-citation
Metadata
- Authors
- Jain, A. K., Gupta, V. K., & Singh, L. P.
- Venue
- Analytical Proceedings including Analytical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1995
- Volume
- 32
- Issue
- 7
- Pages
- 263
- ISSN
- 0144-557X (ISSN-L)
- OpenAlex
- W1985673332
- Cited by
- 195
- References
- 0
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neutral carrier and organic resin based membranes as sensors for uranyl ions. https://app.cochat.ai/papers/10.1039/ai9953200263
- The paper
- Jain, A. K., Gupta, V. K., & Singh, L. P. (1995). Neutral carrier and organic resin based membranes as sensors for uranyl ions. Analytical Proceedings including Analytical Communications. https://doi.org/10.1039/ai9953200263
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.