The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Extraction and high-performance liquid chromatographic method for the determination of microcystins in raw and treated waters
Abstract
Increasing concern over the presence of microcystins (cyanobacterial/blue-green algal hepatotoxins) in water supplies has emphasized the need for a suitable analytical method. As many microcystins are known to exist, a method was developed that permits the determination of numerous variants by a single procedure. The method involves filtration to separate cyanobacterial cells from water, allowing intracellular and extracellular toxin levels to be assessed. The cellular components of the samples are extracted repeatedly in methanol, which was found to be the most versatile solvent tested for the extraction of microcystins. The efficiency of this extraction procedure was found to be independent of cell biomass. The filtered water was subjected to trace enrichment using a C18 solid-phase extraction cartridge, followed by identification and determination by photodiode-array high-performance liquid chromatography. The procedure was assessed using four water samples (two raw and two treated) spiked with a mixture of five microcystins and the cyanobacterial hepatotoxin nodularin. Recoveries of all but one microcystin were found to be good when spiked with concentrations as low as 250 ng l-1. The linearity and precision of the experimental procedure were assessed for five microcystins and nodularin. The proposed method permits rapid sample processing and determination of several microcystins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cyanobacteria secondary metabolites—the cyanotoxins
Carmichael, W. W. (1992) · Journal of Applied Bacteriology · doi:10.1111/j.1365-2672.1992.tb01858.x · Cited by 1,457
Cited by
Microcystin Biosynthesis in Planktothrix : Genes, Evolution, and Manipulation
Christiansen, G., Fastner, J., Erhard, M., Börner, T., & Dittmann, E. (2003) · Journal of Bacteriology · doi:10.1128/jb.185.2.564-572.2003 · Cited by 373
Rivasseau, C., Racaud, P., Deguin, A., & Hennion, M.-C. (1999) · Environmental Science & Technology · doi:10.1021/es980460g · Cited by 61
Metadata
- Authors
- Lawton, L. A., Edwards, C., & Codd, G. A.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1994
- Volume
- 119
- Issue
- 7
- Pages
- 1525
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2022091680
- Cited by
- 655
- References
- 1
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extraction and high-performance liquid chromatographic method for the determination of microcystins in raw and treated waters. https://app.cochat.ai/papers/10.1039/an9941901525
- The paper
- Lawton, L. A., Edwards, C., & Codd, G. A. (1994). Extraction and high-performance liquid chromatographic method for the determination of microcystins in raw and treated waters. The Analyst. https://doi.org/10.1039/an9941901525
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.