Extraction of polycyclic aromatic hydrocarbons from highly contaminated soils using microwave energy
The DOI matches its Crossref record.
Abstract
Microwave energy, generated in a commercial microwave system designed for extraction of organic samples, has been used for the extraction of polycyclic aromatic hydrocarbons (PAHs) from highly contaminated land samples. Initial studies used a native soil and compared a 20 min microwave extraction with a 6 h conventional Soxhlet extraction (both using dichloromethane) with comparable results. The low concentration of PAHs found in the soil resulted in large relative standard deviation (sr) values for the individual PAHs (maximum of 60.9% for microwave extraction). A second soil, with higher PAH levels, was microwave extracted using both dichloromethane and different compositions of an acetone–hexane mixture and compared with Soxhlet extraction. The results indicate that microwave extraction using pure acetone is a more efficient procedure than other combinations studied. A repeatability study gave an sr value for the total PAHs extracted of 2.4%(n= 6). A central composite experimental design was used to elucidate optimum operating parameters but variations in temperature, extraction time and solvent volume were found to have little effect on recovery. The over-all sr for the design was 5.34% illustrating no statistical significance in recovery. A third, Laboratory of the Government Chemist, test soil was used which indicated that the soil matrix was the greatest factor affecting PAH recovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analytical-scale microwave-assisted extraction
Sparr Eskilsson, C., & Björklund, E. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00921-3 · Cited by 1,116
Kaufmann, B., & Christen, P. (2002) · Phytochemical Analysis · doi:10.1002/pca.631 · Cited by 831
“Such systems are generally advised for digestions or acid mineralisations or for extractions under drastic conditions, since the solvents may be heated to ca. 100°C above their atmospheric boiling point (Barnabas et al., 1995; Jassie et al., 1997).”
BackgroundInfluentialSoxhlet extraction of solid materials: an outdated technique with a promising innovative future
Luque de Castro, M. D., & Garcı́a-Ayuso, L. E. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00233-5 · Cited by 727
Microwave-Assisted Extraction of Flavonoids: A Review
Routray, W., & Orsat, V. (2012) · Food and Bioprocess Technology · doi:10.1007/s11947-011-0573-z · Cited by 676
Microwave-assisted solvent extraction of environmental samples
Camel, V (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(99)00185-5 · Cited by 495
Metadata
- Authors
- Barnabas, I. J., Dean, J. R., Fowlis, I. A., & Owen, S. P.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1995
- Volume
- 120
- Issue
- 7
- Pages
- 1897
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1988484165
- Cited by
- 122
- References
- 0
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extraction of polycyclic aromatic hydrocarbons from highly contaminated soils using microwave energy. https://app.cochat.ai/papers/10.1039/an9952001897
- The paper
- Barnabas, I. J., Dean, J. R., Fowlis, I. A., & Owen, S. P. (1995). Extraction of polycyclic aromatic hydrocarbons from highly contaminated soils using microwave energy. The Analyst. https://doi.org/10.1039/an9952001897
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.