Homogeneous liquid–liquid extraction followed by X-ray fluorescence spectrometry of a microdroplet on filter-paper for the simultaneous determination of small amounts of metals
The DOI matches its Crossref record.
Abstract
Homogeneous liquid–liquid extraction with perfluorooctanate ion (PFOA–) was utilized for the preconcentration of certain types of metal chelates, such as diethyldithiocarbamate, 1,10-phenanthroline and desferrioxamine B. Under the experimental conditions {i.e., [PFOA−]T = 6.0 × 10−3 mol l−1, [acetone]T = 2.0 vol%, [HCl]T=0.72 mol l−1, room temperature}, the maximum concentration factor was 500-fold. A method was then developed to determine those metal chelates deposited in a microdroplet on filter-paper using X-ray fluorescence spectrometry. As a result, when three types of chelating agent were used together in the process, 15 metal ions [Ti(IV), Zr(IV), V(V), Nb(V), Ta(V), W(VI), Fe(II), Co(II), Ni(II), Pd(II), Cu(II), Au(III), Hg(II), Bi(III) and Se(IV)] were simultaneously determined. The recovery of each metal was ca. 83–100%, except for W(VI) which was 60.2%. The calibration curves for each metal ion were linear over the range from 5.0 × 10−7 to 1.0 × 10−5 mol l−1. The detection limits were at the 10−8 mol l−1 level and the relative standard deviations were below 5%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Chen, J., & Teo, K. C. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01367-8 · Cited by 355
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.09.005 · Cited by 322
Chen, J., & Teo, K. C. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)00849-2 · Cited by 194
Metadata
- Authors
- Igarashi, S., Takahashi, A., Ueki, Y., & Yamaguchi, H.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2000
- Volume
- 125
- Issue
- 5
- Pages
- 797-798
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2106122958
- Cited by
- 56
- References
- 0
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Homogeneous liquid–liquid extraction followed by X-ray fluorescence spectrometry of a microdroplet on filter-paper for the simultaneous determination of small amounts of metals. https://app.cochat.ai/papers/10.1039/b001581o
- The paper
- Igarashi, S., Takahashi, A., Ueki, Y., & Yamaguchi, H. (2000). Homogeneous liquid–liquid extraction followed by X-ray fluorescence spectrometry of a microdroplet on filter-paper for the simultaneous determination of small amounts of metals. The Analyst. https://doi.org/10.1039/b001581o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.