The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparison between sequential extraction procedures and single extractions for metal partitioning in sewage sludge samples
Abstract
The conventional Tessier and BCR sequential extraction methods were applied to metal partitioning in sewage sludge samples collected from a waste water treatment plant. The results obtained by sequential extraction methods for Cu, Cr, Ni, Pb and Zn were compared with those estimated from single extractions using identical operating conditions applied in each individual Tessier and BCR fraction. The metal content in the extracts was measured by flame atomic absorption spectrometry. In all fractions of the BCR method, and in the three first fractions of the Tessier method, the results obtained from single extractions were in good agreement with those obtained using the sequential procedures. The oxidizable fraction of the Tessier method should be leached from the solid residue of the reducible extraction, since a very low extraction efficiency was obtained for this fraction when it was directly extracted. The total extractable metal contents obtained by both single and sequential extractions were similar for all metals in the BCR method and for Cr, Ni and Pb in the Tessier method. The recoveries obtained ranged from 93.52 to 105.8% in the two studied samples. For Cu and Zn the overall extraction efficiency of the proposed method was slightly lower than that obtained with the sequential procedure (recoveries around 90%). The precision of the proposed Tessier and BCR single extraction methods (expressed as RSD) was lower than 8% for all metals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequential extraction procedure for the speciation of particulate trace metals
Tessier, A., Campbell, P. G. C., & Bisson, M. (1979) · Analytical Chemistry · doi:10.1021/ac50043a017 · Cited by 12,052
Cited by
Chemical sequential extraction for metal partitioning in environmental solid samples.
Filgueiras, A. V., Lavilla, I., & Bendicho, C. (2002) · Journal of Environmental Monitoring · doi:10.1039/b207574c · Cited by 972
Gleyzes, C., Tellier, S., & Astruc, M. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)00603-9 · Cited by 950
Jiang, J., Xu, R.-K., Jiang, T.-Y., & Li, Z. (2012) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2012.05.086 · Cited by 551
Rao, C. R. M., Sahuquillo, A., & Lopez Sanchez, J. F. (2008) · Water, Air, and Soil Pollution · doi:10.1007/s11270-007-9564-0 · Cited by 538
Wragg, J., Cave, M., Basta, N., Brandon, E., Casteel, S., Denys, S., Gron, C., Oomen, A., Reimer, K., Tack, K., et al. (2011) · Science of The Total Environment · doi:10.1016/j.scitotenv.2011.05.019 · Cited by 390
Metadata
- Authors
- Alborés, A. F., Cid, B. P., Gómez, E. F., & López, E. F.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2000
- Volume
- 125
- Issue
- 7
- Pages
- 1353-1357
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2117690277
- Cited by
- 176
- References
- 1
- FWCI
- 5.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison between sequential extraction procedures and single extractions for metal partitioning in sewage sludge samples. https://app.cochat.ai/papers/10.1039/b001983f
- The paper
- Alborés, A. F., Cid, B. P., Gómez, E. F., & López, E. F. (2000). Comparison between sequential extraction procedures and single extractions for metal partitioning in sewage sludge samples. The Analyst. https://doi.org/10.1039/b001983f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.