Performance evaluation of a sorbent tube sampling method using short path thermal desorption for volatile organic compounds
The DOI matches its Crossref record.
Abstract
Air sampling, using sorbents, thermal desorption and gas chromatography, is a versatile method for identifying and quantifying trace levels of volatile organic compounds (VOCs). Thermal desorption can provide high sensitivity, appropropriate choices of sorbents and method parameters can accommodate a wide range of compounds and high humidity, and automated short-path systems can minimize artifacts, losses and carry-over effects. This study evaluates the performance of a short-path thermal desorption method for 77 VOCs using laboratory and field tests and a dual sorbent system (Tenax GR, Carbosieve SIII). Laboratory tests showed that the method requirements for ambient air sampling were easily achieved for most compounds, e.g., using the average and standard deviation across target compounds, blank emissions were < or = 0.3 ng per sorbent tube for all target compounds except benzene, toluene and phenol; the method detection limit was 0.05 +/- 0.08 ppb, reproducibility was 12 +/- 6%, linearity, as the relative standard deviation of relative response factors, was 16 +/- 9%, desorption efficiency was 99 +/- 28%, samples stored for 1-6 weeks had recoveries of 87 +/- 9%, and high humidity samples had recoveries of 102 +/- 12%. Due to sorbent, column and detector characteristics, performance was somewhat poorer for phenol groups, ketones, and nitrogen containing compounds. The laboratory results were confirmed in an analysis of replicate samples collected in two field studies that sampled ambient air along roadways and indoor air in a large office building. Replicates collected under field conditions demonstrated good agreement except for very low concentrations or large (> 41 volume) samples of high humidity air. Overall, the method provides excellent performance and satisfactory throughput for many applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Critical Review of Naphthalene Sources and Exposures Relevant to Indoor and Outdoor Air
Jia, C., & Batterman, S. (2010) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph7072903 · Cited by 312
Self-citationIndoor air quality in Michigan schools
Godwin, C., & Batterman, S. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00459.x · Cited by 263
Self-citationLevels and sources of volatile organic compounds in homes of children with asthma
Chin, J.-Y., Godwin, C., Parker, E., Robins, T., Lewis, T., Harbin, P., & Batterman, S. (2014) · Indoor Air · doi:10.1111/ina.12086 · Cited by 165
“Method detection limits (MDLs) were determined for each VOC as the standard deviation of 7 replicate low concentration measurements, using standard solutions spiked into the thermal desorption tubes, multiplied by 3.14 (Peng and Batterman, 2000).”
MethodInfluentialSelf-citationHalogenated Volatile Organic Compounds from the Use of Chlorine-Bleach-Containing Household Products
Odabasi, M. (2008) · Environmental Science & Technology · doi:10.1021/es702355u · Cited by 159
VOC sources and exposures in nail salons: a pilot study in Michigan, USA
Zhong, L., Batterman, S., & Milando, C. W. (2019) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-018-1353-0 · Cited by 62
Self-citationAnalysis of trihalomethanes in water and air from indoor swimming pools using HS-SPME/GC/ECD
Sá, C. S. A., Boaventura, R. A. R., & Pereira, I. B. (2011) · Journal of Environmental Science and Health, Part A · doi:10.1080/10934529.2011.542385 · Cited by 38
“[ 33 , 34 , 35 ] In these reports the sampling technique included sorbent tubes and thermal desorption.”
Metadata
- Authors
- Peng, C.-Y., & Batterman, S.
- Venue
- Journal of Environmental Monitoring
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2000
- Volume
- 2
- Issue
- 4
- Pages
- 313-324
- ISSN
- 1464-0325 (ISSN-L)
- 1464-0333
- OpenAlex
- W1981392314
- Cited by
- 96
- References
- 0
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.