The DOI matches its Crossref record.
Molecularly imprinted polymer sensors for pesticide and insecticide detection in water
Abstract
Antibodies, peptides, and enzymes are often used as molecular recognition elements in chemical and biological sensors. However, their lack of stability and signal transduction mechanisms limits their use as sensing devices. Recent advances in the field of molecularly imprinted polymers (MIPs) have created synthetic materials that can mimic the function of biological receptors but with less stability constraints. These polymers can provide high sensitivity and selectivity while maintaining excellent thermal and mechanical stability. To further enhance the advantages of the traditional imprinted polymer approach, an additional fluorescent component has been introduced into these polymers. Such a component provides enhanced chemical affinity as well as a method for signal transduction. In this type of imprinted polymer, binding of the target analyte invokes a specific spectral signature from the reporter molecule. Previous work has provided molecularly imprinted polymers that are selective for the hydrolysis products of organophosphorus species such as the nerve agents sarin and soman. (A. L. Jenkins, O. M. Uy and G. M. Murray, Anal. Chem., 1999, 71, 373). In this paper the direct imprinting of non-hydrolyzed organophosphates including pesticides and insecticides is described. Detection limits for these newly developed MIP sensors are less than 10 parts per trillion (ppt) with long linear dynamic ranges (ppt to ppm) and response times of less than 15 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alexander, C., Andersson, H. S., Andersson, L. I., Ansell, R. J., Kirsch, N., Nicholls, I. A., O'Mahony, J., & Whitcombe, M. J. (2006) · Journal of Molecular Recognition · doi:10.1002/jmr.760 · Cited by 1,248
Biosensors as useful tools for environmental analysis and monitoring
Rodriguez-Mozaz, S., Lopez de Alda, M. J., & Barceló, D. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0574-3 · Cited by 451
Samsidar, A., Siddiquee, S., & Shaarani, S. M. (2018) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2017.11.011 · Cited by 416
Electrochemical sensors based on molecularly imprinted polymers
Blanco-López, M. C., Lobo-Castañón, M. J., Miranda-Ordieres, A. J., & Tuñón-Blanco, P. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00102-5 · Cited by 382
Biosensor Technology for Pesticides—A review
Verma, N., & Bhardwaj, A. (2015) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-015-1489-2 · Cited by 284
Metadata
- Authors
- Jenkins, A. L., Yin, R., & Jensen, J. L.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001
- Volume
- 126
- Issue
- 6
- Pages
- 798-802
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2043493734
- Cited by
- 175
- References
- 0
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecularly imprinted polymer sensors for pesticide and insecticide detection in water. https://app.cochat.ai/papers/10.1039/b008853f
- The paper
- Jenkins, A. L., Yin, R., & Jensen, J. L. (2001). Molecularly imprinted polymer sensors for pesticide and insecticide detection in water. The Analyst. https://doi.org/10.1039/b008853f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.