The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Molecular composition and orientation at the surface of room-temperature ionic liquids: Effect of molecular structure
Abstract
We have used direct recoil spectrometry (DRS) to investigate the composition and molecular orientation at the surfaces of a variety of room-temperature ionic liquids of the general type [Cnmim]X where [Cnmim] = 1-CnH2n+1-3-methylimidazolium cation (n = 4 (bmim), 8 (omim), 12 (C12mim)) and X is [PF6]−, [BF4]−, Cl− or Br−. Comparing experimental atomic F/C and H/C ratios for [Cnmim][PF6] (n = 4, 8, 12) or [Cnmim][BF4] (n = 4, 8) with predicted ratios for various surface compositions suggests that the surface is populated by both anions and cations with no segregation. The data best fit the cation ring being perpendicular rather than parallel to the surface. The data for the cations of fluorine-containing liquids support a common orientation with the N atoms of the ring uppermost. The cations of the shorter chain hexafluorophosphate liquids appears to stay within a rotation angular spread of about ± 30° from this orientation but increasing the alkyl chain length to 12 carbon atoms favors a tilt of ∼45° to bring the Me group closer to the surface. Changing to the smaller [BF4]− anion has a similar effect. For [omim][Cl], the data fit best for a cation orientation with either N-up or N-down and the methyl group tilted towards the surface in a similar manner to [omim][BF4]. In the case of [omim][Br], a number of cation orientations are compatible with the data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
Self-citation
Cited by
Multiscale Studies on Ionic Liquids
Dong, K., Liu, X., Dong, H., Zhang, X., & Zhang, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00776 · Cited by 773
Brønsted Acid−Base Ionic Liquids as Proton-Conducting Nonaqueous Electrolytes
Noda, A., Susan, M. A. B. H., Kudo, K., Mitsushima, S., Hayamizu, K., & Watanabe, M. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp022347p · Cited by 683
Microstructural and Dynamical Heterogeneities in Ionic Liquids
Wang, Y.-L., Li, B., Sarman, S., Mocci, F., Lu, Z.-Y., Yuan, J., Laaksonen, A., & Fayer, M. D. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00693 · Cited by 465
Surface tensions of imidazolium based ionic liquids: Anion, cation, temperature and water effect
Freire, M. G., Carvalho, P. J., Fernandes, A. M., Marrucho, I. M., Queimada, A. J., & Coutinho, J. A. P. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2007.06.003 · Cited by 440
Steinrück, H.-P., & Wasserscheid, P. (2015) · Catalysis Letters · doi:10.1007/s10562-014-1435-x · Cited by 402
Metadata
- Authors
- Law, G., Watson, P. R., Carmichael, A. J., & Seddon, K. R.
- Venue
- Physical Chemistry Chemical Physics
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001
- Volume
- 3
- Issue
- 14
- Pages
- 2879-2885
- ISSN
- 1463-9076 (ISSN-L)
- 1463-9084
- OpenAlex
- W2068266245
- Cited by
- 171
- References
- 1
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.