The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Headspace extraction of alcohols into a single drop
Abstract
The possibility of applying headspace microextraction into a single drop for the determination of alcohols in aqueous solutions is demonstrated. A drop of ethylene glycol containing butan-2-one as an internal standard is used for extraction. The analytes are extracted by suspending a 1 μl extracting drop directly from the tip of a microsyringe fixed above an extraction vial with a septum such that the needle passes through the septum and the needle tip appears above the surface of the solution. After the extraction is finished the drop is retracted back into the needle and injected directly into a GC column. Optimization of experimental conditions (sampling time, sampling temperature, stirring rate and ionic strength of the solution) with respect to the extraction efficiency were investigated and the linear range and the precision were examined. This headspace single drop microextraction method was applied to the analysis of beer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Cited by
New horizons in the extraction of bioactive compounds using deep eutectic solvents: A review
Zainal-Abidin, M. H., Hayyan, M., Hayyan, A., & Jayakumar, N. S. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.05.012 · Cited by 637
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Sample preparation techniques for the determination of trace residues and contaminants in foods
Ridgway, K., Lalljie, S. P. D., & Smith, R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.134 · Cited by 354
Vortex-assisted liquid–liquid microextraction of octylphenol, nonylphenol and bisphenol-A
Yiantzi, E., Psillakis, E., Tyrovola, K., & Kalogerakis, N. (2010) · Talanta · doi:10.1016/j.talanta.2009.11.005 · Cited by 338
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Metadata
- Authors
- Tankeviciute, A., Kazlauskas, R., & Vickackaite, V.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001
- Volume
- 126
- Issue
- 10
- Pages
- 1674-1677
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2082321280
- Cited by
- 202
- References
- 2
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Headspace extraction of alcohols into a single drop. https://app.cochat.ai/papers/10.1039/b103493f
- The paper
- Tankeviciute, A., Kazlauskas, R., & Vickackaite, V. (2001). Headspace extraction of alcohols into a single drop. The Analyst. https://doi.org/10.1039/b103493f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.