Liquid-phase microextraction of protein-bound drugs under non-equilibrium conditions
The DOI matches its Crossref record.
Abstract
Recently, we introduced an inexpensive and disposable hollow fiber-based device for liquid-phase microextraction (LPME) where ionic analytes typically were extracted and preconcentrated from 1-4 mL aqueous samples (such as plasma and urine) through an organic solvent immobilized in the pores of a polypropylene hollow fiber and into a 10-25 microL volume of acceptor phase present inside the lumen of the hollow fiber. Subsequently, the acceptor phase was directly subjected to the final analysis by a chromatographic or electrophoretic method. In the present work, attention was focused on LPME of the basic drugs amphetamine, pethidine, promethazine, methadone and haloperidol characterized by substantial differences in the degree of protein binding. Drug-protein interactions in plasma resulted in reduced recoveries and substantially increased extraction times compared with extraction of the drugs from a pure water matrix. However, by addition of 5-50% methanol to the plasma samples, recoveries were comparable with LPME from water samples and ranged between 75 and 100%. The addition of methanol was found not to speed up the LPME process and extractions from plasma were performed in 45 min to reach equilibrium. Because approximately 55-70% of the final analyte concentrations were achieved within the initial 10 min of the LPME process, validation was accomplished after 10 and 45 min of LPME. In general, the results with 10 and 45 min were almost comparable, with precision data in the range 1.2-11.1% (RSD) and with linearity in the concentration range 20-1000 ng mL(-1) (r = 0.999). In conclusion, excellent LPME results may be achieved in a short time under non-equilibrium conditions with a minor loss of sensitivity. In cases of drug-protein interactions, methanol may be added to ensure a high extraction recovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Self-citationPedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Self-citationLee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Self-citationNew trends in sample preparation for clinical and pharmaceutical analysis
Kataoka, H. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)00402-3 · Cited by 261
Rezaei, F., Bidari, A., Birjandi, A. P., Milani Hosseini, M. R., & Assadi, Y. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.02.005 · Cited by 164
Ozcan, S., Tor, A., & Aydin, M. E. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.037 · Cited by 113
The role of microextraction techniques in occupational exposure assessment. A review
Jalili, V., Barkhordari, A., & Norouzian Baghani, A. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.104086 · Cited by 35
Metadata
- Authors
- Ho, T. S., Pedersen-Bjergaard, S., & Rasmussen, K. E.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002-04-10
- Volume
- 127
- Issue
- 5
- Pages
- 608-613
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2007229044
- Cited by
- 82
- References
- 0
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.