The DOI matches its Crossref record.
Carbon nanotube-modified electrodes for the simultaneous determination of dopamine and ascorbic acid
Abstract
The voltammetric separation of dopamine and ascorbic acid was studied with cyclic voltammetry at two kinds of carbon nanotube-modified electrodes (coated and intercalated). The anodic peak difference reached 270 mV under the present conditions. The separation mechanism and effect factors were carefully studied. Using various types of surfactants as coating dispersants of carbon nanotubes, it was demonstrated that the charge nature of the surfactants had a strong effect on the electrochemical behavior of dopamine and ascorbic acid. When the oxidation solution of carbon nanotubes was changed from the most commonly used mixed concentrated nitric acid and sulfuric acid (1 + 3 v/v) to dilute nitric acid and to hydrochloric acid, the anodic peak separation value of dopamine and ascorbic acid increased significantly, and it was shown that carboxylic acid groups attached to the carbon nanotubes were an adverse factor for the discrimination of DA from AA. These results indicated that the resolution of DA and AA was mainly attributable to the stereo porous interfacial layer formed from aggregated pores and inner cavities of the carbon nanotubes. The modified electrodes exhibited an attractive ability to measure DA and AA simultaneously and showed good stability and reproducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Solubilization of Carbon Nanotubes by Nafion toward the Preparation of Amperometric Biosensors
Wang, J., Musameh, M., & Lin, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028951v · Cited by 1,382
Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene
Shan, C., Yang, H., Song, J., Han, D., Ivaska, A., & Niu, L. (2009) · Analytical Chemistry · doi:10.1021/ac802193c · Cited by 1,315
Nanotechnology applications in cancer
Nie, S., Xing, Y., Kim, G. J., & Simons, J. W. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.152025 · Cited by 952
Lu, J., Do, I., Drzal, L. T., Worden, R. M., & Lee, I. (2008) · ACS Nano · doi:10.1021/nn800244k · Cited by 438
Metadata
- Authors
- Wang, Z., Liu, J., Liang, Q., Wang, Y., & Luo, G.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002-04-18
- Volume
- 127
- Issue
- 5
- Pages
- 653-658
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2018186033
- Cited by
- 468
- References
- 0
- FWCI
- 26.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon nanotube-modified electrodes for the simultaneous determination of dopamine and ascorbic acid. https://app.cochat.ai/papers/10.1039/b201060g
- The paper
- Wang, Z., Liu, J., Liang, Q., Wang, Y., & Luo, G. (2002). Carbon nanotube-modified electrodes for the simultaneous determination of dopamine and ascorbic acid. The Analyst. https://doi.org/10.1039/b201060g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.