An evaporation-based microfluidic sample concentration method
The DOI matches its Crossref record.
Abstract
We present a method for sample concentration within microfluidic devices using evaporation-induced flow. Evaporation-induced flow is easy to incorporate into microfluidic designs and can be used to concentrate a wide variety of molecules. The practicality of this method was demonstrated with 0.2 microm fluorescent spheres and FITC-labeled BSA. Thirty two percent of the 0.6 microL fluorescent sphere suspension was concentrated into a well within a microfluidic device. In the same amount of time, 93% of the 0.6 microL FITC-labeled BSA solution was concentrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Self-citationComputerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Particle concentration and mixing in microdrops driven by focused surface acoustic waves
Shilton, R., Tan, M. K., Yeo, L. Y., & Friend, J. R. (2008) · Journal of Applied Physics · doi:10.1063/1.2951467 · Cited by 311
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Berthier, E., Warrick, J., Yu, H., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b717422e · Cited by 114
Self-citationKuo, C.-T., Liu, H.-K., Huang, G.-S., Chang, C.-H., Chen, C.-L., Chen, K.-C., Yun-Ju Huang, R., Lin, C.-H., Lee, H., Huang, C.-S., et al. (2014) · The Analyst · doi:10.1039/c4an00936c · Cited by 20
Metadata
- Authors
- Walker, G. M., & Beebe, D. J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002
- Volume
- 2
- Issue
- 2
- Pages
- 57
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2101651250
- Cited by
- 106
- References
- 0
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.