A batch of 77Se-labelled and enriched yeast was characterised with regard to isotopic composition and content of selenium species for later use in a human absorption study based on the method of enriched stable isotopes. The abundance of the six stable selenium isotopes was determined by ICP-MS equipped with a dynamic reaction cell (DRC). The results showed that the 77Se isotope was enriched to 98.5 atom-%, whereas the remaining selenium was present as the other five isotopes at low abundance. The low-molecular 77Se containing species, which were biosynthesised by the yeast during fermentation using the enriched 77Se-selenite as substrate, were released by enzymatic hydrolysis using (I), a β-glucosidase followed by a protease mixture, and (II), a commercial protease preparation. For selenium speciation the chromatographic selectivity of the cation exchange HPLC system was adjusted to the separation of over 30 selenium species occurring in the hydrolysates by applying gradient elution using pyridinium formate as mobile phase. The quantitative results obtained by detection with ICP-DRC-MS of 77Se and 80Se showed that both enzymatic sample preparation systems released 90–95% of the yeast's selenium content. The total area of the cation exchange chromatograms, however, amounted to 64% of the total selenium content in the yeast, which was 1390 µg g−1. In the enzymatic extracts selenomethionine (SeMet) constituted 82% of all separated and quantified selenium species, which was equivalent to 53% of the total selenium content in the yeast. Oxidation of SeMet to selenomethionine-Se-oxide (SeOMet) occurred during sample preparation. The degree of formation of SeOMet was large and variable when using enzyme system I, but low when using enzyme II.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b209586f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Larsen, E. H., Sloth, J., Hansen, M., & Moesgaard, S.
Venue
Journal of Analytical Atomic Spectrometry
Published
2003-03-18
Volume
18
Issue
4
Pages
310-316
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2107308407
Cited by
80
References
1
FWCI
8.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.