CoChat

Determination of arsenic by electrothermal atomic absorption spectrometry using headspace liquid phase microextraction after in situ hydride generation

Chamsaz, Mahmoud, Arbab-Zavar, Mohammad Hossein, Nazari, Saeid · 2003 · Journal of Analytical Atomic Spectrometry

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

A novel and extremely highly sensitive method for extraction and determination of arsenic in aqueous samples by headspace liquid phase microextraction combined with graphite furnace atomic absorption spectrometry is described. The arsenic species were converted to arsine in 3 mol dm−3 HCl sample solution by sodium tetrahydroborate (NaBH4) in a closed headspace vial and during the 7 min extraction time at 35 °C it was reacted with AgDDC dissolved in a 4 µl microdrop mixture of 1∶3 pyridine∶benzyl alcohol suspended in the tip of a microsyringe. After the equilibrium between the arsine in the headspace and microdrop has been reached, the microdrop was retracted and directly transferred into a graphite furnace for determination of arsenic. Using 2 ml sample solution, an enrichment factor of 150 could be obtained with an overall efficiency of HG, transport and trapping of 30%. The detection limit was calculated to be 45 pg ml−1 based on 3 sb with an absolute value of 0.18 pg for a 4 µl injection into the graphite furnace. The relative standard deviation for five replicate analyses of 4 ng ml−1 arsenic was 8.6%. The characteristic concentration was 30 pg ml−1 equivalent to a characteristic mass of 0.12 pg with a calibration curve linear in the range of 45 pg ml−1 to 4 ng ml−1. The effects of interferences were also investigated. The results for determination of arsenic in reference materials, tap water, washing machine powder and spiked seawater demonstrated the accuracy, recovery…

Overview

Integrity signals

Registry

Crossref · 10.1039/b303169a

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Cited by

See all 83

Metadata

Authors
Chamsaz, M., Arbab-Zavar, M. H., & Nazari, S.
Affiliations
Ferdowsi University of Mashhad (IR)
Corresponding author
Chamsaz, Mahmoud
Venue
Journal of Analytical Atomic Spectrometry
Published
2003
Volume
18
Issue
10
Pages
1279
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2065586186
Cited by
83
References
19
Citations by year
2026: 1 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 1 · 2021: 3 · 2020: 3 · 2019: 5 · 2018: 1 · 2017: 1 · 2016: 3 · 2015: 2 · 2014: 6 · 2013: 3 · 2012: 4
FWCI
1.74
Type
journal article
Language
en
Open access
closed
Locations
Journal of Analytical Atomic Spectrometry (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Environmental Science › Environmental Chemistry › Arsenic contamination and mitigation
Keywords
arsenic determination, arsine, sodium tetrahydroborate, graphite furnace atomic absorption spectrometry, enrichment factor, trace analysis, aqueous sample, seawater, tap water

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of arsenic by electrothermal atomic absorption spectrometry using headspace liquid phase microextraction after in situ hydride generation. https://app.cochat.ai/papers/10.1039/b303169a
The paper
Chamsaz, M., Arbab-Zavar, M. H., & Nazari, S. (2003). Determination of arsenic by electrothermal atomic absorption spectrometry using headspace liquid phase microextraction after in situ hydride generation. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/b303169a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.