Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Accurate isotope ratio measurements of ytterbium by multiple collection inductively coupled plasma mass spectrometry applying erbium and hafnium in an improved double external normalization procedure

Segal, Irina, Halicz, Ludwik, Platzner, Itzhak T. · 2003 · Journal of Analytical Atomic Spectrometry

Abstract

Four series of experiments had been carried out for correct ytterbium isotope ratios measurements (IRM). (1) For erbium IRM, 167Er/166Er = 0.68260, derived from recently published thermal ionization mass spectrometry (TIMS) measurements, was applied as an internal normalization factor. (2) Ytterbium has no calibrated isotope ratio values. In an erbium–ytterbium–hafnium mixture solution we determined (171Yb/172Yb)Er-corr = 0.653436(4) using the above 167Er/166Er ratio as external normalization factor. In the same mixture we also determined (171Yb/172Yb)Hf-corr = 0.653297(25) using the well-known IUPAC value for the ratio 179Hf/177Hf = 0.73250 as external normalization factor. In these measurements no atomic isobaric interference exists at the corresponding mass numbers. (3) These two 171Yb/172Yb ratios, derived with data at mass intervals 166–167 and ∼178, were interpolated to mass interval 171–172, applying linear and slightly curved (exponential) line interpolations. 171Yb/172Yb = 0.653367 and 0.653344 are the linear and curved line interpolated values, respectively. Then, all ytterbium isotope ratios were measured in pure ytterbium solutions and internally corrected with each of the two 171Yb/172Yb ratios. (4) Using the literature value for 178Hf/177Hf = 1.467290, we obtained 179Hf/177Hf = 0.73249(2), which is in very good agreement with the above mentioned IUPAC value. The exponential correction equation was applied in this work. The mean Er ratio values are in good agreement with literature, except for the 162Er/166Er ratio, which is 2.19% lower than the reported absolute TIMS value. The mean Yb ratio values obtained in this work are in fair agreement with data reported in the last 25 years. We believe that they are the closest to the true values. The precision (2σ) is at least 3–8 times better comparing to the measured TIMS precision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b307016f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Segal, I., Halicz, L., & Platzner, I. T.
Venue
Journal of Analytical Atomic Spectrometry
Published
2003
Volume
18
Issue
10
Pages
1217
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2061188678
Cited by
230
References
1
FWCI
2.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.